Skip to main content
Siemens 5SY6215-8CC — 2-Pole MCB (DIN Rail)

Siemens 5SY6215-8CC SENTRON MCB, 1.6A D-Curve, 2-Pole, 400V

MPN5SY6215-8CC

Siemens SENTRON 5SY6CC series miniature circuit breaker, 2-pole, D characteristic, 1.6 A rated current, 400 V AC, 6 kA breaking capacity per EN 60898, 5SY6215-8CC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY6215-8CC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentMechanical engineering / industry
5SY6215-8CC — Electrical
ParameterValue
Number of poles2
5SY6215-8CC — Protection
ParameterValue
Tripping characteristic classD
Overvoltage categoryIII
5SY6215-8CC — Mechanical
ParameterValue
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Protection degree (IP)IP20, with connected conductors

Product details

Siemens 5SY6215-8CC — SENTRON 2-Pole D-Curve MCB, 1.6 A

The Siemens 5SY6215-8CC is a 2-pole miniature circuit breaker from the SENTRON 5SY6CC series, rated at 1.6 A with a D tripping characteristic and a rated voltage of 400 V AC. The 1.6 A rating means it's sized for smaller auxiliary circuits, not main feeder protection. Breaking capacity is 6 kA per EN 60898 at 400 V AC, with a 5 kA rating under UL 1077 / CSA C22.2 No. 235 for North American installations. That's adequate for most industrial panel secondary circuits where the upstream fault current is limited.

For buyers maintaining a BOM freeze, this part is a stable line item. If a second-source or alternate form factor is ever needed, the SENTRON 5SY series includes several 2-pole D-curve variants at different current ratings — but the 5SY6215-8CC itself is the 1.6 A code in the 5SY6CC design.

Integration — panel fit and wiring

Overall dimensions: 90 mm height, 76 mm depth. Terminals accept solid or stranded conductors from 0.75 to 35 mm², with a tightening torque range of 2.5 to 3.5 N·m. Both top and bottom terminals are combined (phase + neutral busbar compatible), though the unit does not switch the neutral — it's a 2-pole MCB protecting both phase conductors in a single-phase or split-phase circuit.

Humidity tolerance: max 95% at 55 °C, derating to 55% at 70 °C and 35% at 75 °C. The unit is sealable (tamper-evident provision) and carries touch protection per the product feature. Mounting position is any orientation; supply cord entry can be from top or bottom (any position). Rated frequency 50/60 Hz.

Frequently asked questions

What is the breaking capacity of 5SY6215-8CC?

6 kA at 400 V AC per EN 60898, and 5 kA per UL 1077 / CSA C22.2 No. 235. This is sufficient for most industrial panel secondary circuits with limited upstream fault current.

What conductor sizes does the 5SY6215-8CC accept?

Solid or stranded conductors from 0.75 mm² up to 35 mm². The screw terminals require a tightening torque of 2.5 to 3.5 N·m.

Will 5SY6215-8CC drop into a panel specified for 5SY3132-6?

Both are 2-pole SENTRON MCBs on the same DIN-rail footprint (36 mm wide, 2 width units). The 5SY3132-6 carries a different current rating and tripping characteristic — check your BOM current requirement before swapping. Physical fit is identical; electrical fit depends on the load.

Where can I buy 5SY6215-8CC and how is it quoted?

Sourced and quoted to order through independent distribution against an RFQ. Availability and current pricing are confirmed at quote time — submit an inquiry for a firm price and lead time.

What compliance documentation is available for 5SY6215-8CC?

The unit carries ratings per EN 60898 and UL 1077 / CSA C22.2 No. 235, indicating third-party certification for those standards. The housing is halogen-free and silicon-free. Full RoHS/REACH declarations are typically available from Siemens on request.

MPN