Skip to main content
Siemens 5SY6230-7 — 2-Pole MCB (DIN Rail)

Siemens 5SY6230-7 SENTRON MCB, 2P C-Curve, 6kA/15kA

MPN5SY6230-7
Active

Siemens SENTRON 5SY6230-7, 2-pole miniature circuit breaker, C-curve, 6 kA (EN 60898-1) / 15 kA (IEC 60947-2), 400 VAC, 50/60 Hz, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SY6230-7 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentMechanical engineering / industry
5SY6230-7 — Electrical
ParameterValue
Number of poles2
5SY6230-7 — Protection
ParameterValue
Tripping characteristic classC
Overvoltage categoryIII
5SY6230-7 — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SY6230-7 — Environmental
ParameterValue
Pollution degree3
5SY6230-7 — Specifications
ParameterValue
At AC rated value400 V
According to EN 60898 rated value6 kA
With single-phase operation at AC rated value440 V
Energy Limitation Class3

Product details

Siemens 5SY6230-7 SENTRON — C-curve 2-pole MCB for panel protection

The Siemens 5SY6230-7 is a 2-pole miniature circuit breaker from the SENTRON series, with a C-curve tripping characteristic. It protects branch circuits against overload and short-circuit in commercial and industrial panels. The C-curve (5–10× In) is the standard choice for inductive or moderate inrush loads — motor starters, contactor coils, small transformers — where a B-curve would nuisance-trip on startup and a D-curve would delay too long for conductor protection. Rated 400 VAC at 50/60 Hz, it carries dual breaking capacities: 6 kA per IEC/EN 60898-1 for residential/commercial application, and 15 kA per IEC 60947-2 for industrial duty where higher fault current is expected. The 15 kA rating under 60947-2 is the one that governs fit in most panelboards — it means this breaker can safely interrupt a 15 kA prospective fault without welding contacts or cascading failure upstream. At 2 modular-width units (36 mm wide), it snaps onto standard DIN rail via the quick-assembly system and mounts in any orientation. Depth is 76 mm; installation depth is 70 mm, so it fits flush in shallow enclosures. The IP20 rating applies with conductors connected — fine for enclosed panels, not for wet or dust-exposed locations.

Frequently asked questions

What compliance documentation does Siemens provide for 5SY6230-7?

The breaker is certified to IEC/EN 60898-1, IEC/EN 60947-2, and UL 1077. It is halogen-free and silicon-free. Standard documentation includes the declaration of conformity, CE marking, and UL recognition. Specific certificates (CSA, EAC, UKCA) should be confirmed at quote time if required for a particular jurisdiction.

MPN
5SY6230-7