Siemens 5SY6280-7CC SENTRON MCB, 2P C 80A 6kA 400V

MPN5SY6280-7CC

Siemens SENTRON 5SY6280-7CC, miniature circuit breaker, 2-pole, C-curve, 80 A, 6 kA per IEC 60947-2 at 400 V AC, 2 MW, IP20.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

5SY6280-7CC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentMechanical engineering / industry

Electrical

5SY6280-7CC — Electrical
ParameterValue
Number of poles2

Protection

5SY6280-7CC — Protection
ParameterValue
Tripping characteristic classC
Overvoltage categoryIII

Mechanical

5SY6280-7CC — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors

Environmental

5SY6280-7CC — Environmental
ParameterValue
Pollution degree3

Specifications

5SY6280-7CC — Specifications
ParameterValue
At AC rated value400 V
With single-phase operation at AC rated value440 V

Product details

The Siemens SENTRON 5SY6280-7CC is a 2-pole miniature circuit breaker with a C tripping characteristic, rated 80 A and a breaking capacity of 6 kA per IEC 60947-2 at 400 V AC. It occupies 2 modular width units (36 mm) on a DIN rail, making it a standard panel-building component for branch-circuit protection in industrial control cabinets.

Ratings and what they mean for fit

The 6 kA breaking capacity at 400 V AC per IEC 60947-2 is the short-circuit current the breaker can safely interrupt. For a panel fed from a transformer or a distribution board with a prospective fault current up to 6 kA, this MCB clears the fault without external fusing. The C-curve (5–10× In) is sized for moderate inrush loads — motor starters, small transformers, banks of LED drivers — where the magnetic trip must not nuisance-trip on startup. The 80 A rating on a 2-pole format suits larger subfeeds or high-current single-phase loads. The 5.6 W power loss per pole at rated current in hot state matters for thermal management inside a sealed enclosure; adjacent devices should be derated per the manufacturer's grouping rules.

Deployment context

Rated for mechanical engineering and industry applications per the specification, this MCB mounts in any position on a DIN rail via the quick-assembly system. The IP20 rating (with connected conductors) is standard for dry indoor panels; the pollution degree 3 and overvoltage category III ratings confirm it is designed for fixed installations inside an enclosure where transient overvoltages from the mains are expected.

Frequently asked questions

What is the breaking capacity of 5SY6280-7CC?

The breaking capacity is 6 kA per IEC 60947-2 at 400 V AC. This is the maximum fault current the breaker can safely interrupt under standard test conditions.

How do I get current pricing and availability for 5SY6280-7CC?

Submit an RFQ through this listing. Pricing and stock status are confirmed at quote time; the part is sourced through independent distribution channels.

What is the width of 5SY6280-7CC in modular units?

It occupies 2 modular width units, equivalent to 36 mm on a standard DIN rail.