Skip to main content
Siemens 5SY6301-7CC — 3-Pole MCB (DIN Rail)

Siemens 5SY6301-7CC SENTRON MCB, 1 A, C-Curve, 3-Pole, 6 kA

MPN5SY6301-7CC

Siemens SENTRON miniature circuit breaker, 5SY6301-7CC, 1 A rated, C tripping characteristic, 3-pole, 6 kA breaking capacity per EN 60898, 50/60 Hz, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY6301-7CC — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationMechanical engineering / industry
5SY6301-7CC — Protection
ParameterValue
Tripping characteristic (curve)C
Breaking capacity per EN 608986 kA
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Energy limitation class3
Pollution degree3
5SY6301-7CC — Electrical
ParameterValue
Rated voltage (AC, multi-phase)440 V
Voltage type (AC/DC)AC
Supply frequency range50/60 Hz
Power loss per pole at rated current (AC, hot)1.2 W
Mechanical service life (operating cycles, typ.)10 000
Neutral conductor switchingNo
Rated voltage (AC, single-phase)440 V
5SY6301-7CC — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
Combined terminal, topYes
Combined terminal, bottomYes
Fastening methodQuick assembly system
SealableYes
Accepts supplementary devicesYes
5SY6301-7CC — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of surrounding temperaturemax. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
Vibration resistance (IEC 60068-2-6)±1mm at 5 to 25Hz; 50m/s² at 25 to 150Hz

Product details

The Siemens 5SY6301-7CC is a SENTRON miniature circuit breaker (MCB) rated 1 A with a C tripping characteristic, 3-pole design, and a 6 kA breaking capacity per EN 60898.

The 1 A rating at 35 °C drops to 0.94 A at 40 °C, 0.91 A at 45 °C, 0.88 A at 50 °C, and 0.84 A at 55 °C — so if your panel ambient runs above 35 °C, you must derate the breaker or step up to the next amp size.

Dimensions: 76 mm deep, 54 mm wide (3 MW), 90 mm tall. Installation depth is 70 mm. The quick-assembly fastening method snaps onto standard DIN rail. Sealable — useful for metering or isolation applications where tamper evidence is required. Halogen-free and silicon-free construction avoids corrosive outgassing in sealed enclosures.

Frequently asked questions

What is 5SY6301-7CC's rated current and breaking capacity?

Rated 1 A at 35 °C with a C tripping characteristic and 6 kA breaking capacity per EN 60898, 3-pole, AC 50/60 Hz.

Where can I buy 5SY6301-7CC?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What compliance documentation does Siemens provide for 5SY6301-7CC?

The part carries EN 60898 certification for breaking capacity, is halogen-free and silicon-free, and is rated for pollution degree 3 and overvoltage category III — typical for CE-marked industrial control gear.

MPN
5SY6301-7CC