Skip to main content
Siemens 5SY6302-6CC — Miniature Circuit Breakers (MCB)

Siemens 5SY6302-6CC SENTRON MCB, Type B, 2A, 3P, 6kA

MPN5SY6302-6CC

Siemens SENTRON 5SY6302-6CC, Type B miniature circuit breaker, 2 A rated, 3-pole, 6 kA breaking capacity per EN 60898, 3 modular width units.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SY6302-6CC — Ratings
ParameterValue
Overvoltage categoryIII
5SY6302-6CC — Mechanical
ParameterValue
Width54 mm
Height90 mm
Depth76 mm

Product details

SENTRON 5SY6302-6CC — Type B 2 A MCB for 3-pole protection

The Siemens 5SY6302-6CC is a SENTRON miniature circuit breaker with a Type B tripping characteristic, rated 2 A at 35 °C, 3-pole construction, and a 6 kA breaking capacity per EN 60898. Rated current is temperature-dependent: at 40 °C it derates to 1.91 A, at 50 °C to 1.81 A, and at 55 °C to 1.75 A. The surrounding temperature influence limits are specified up to 75 °C, with humidity constraints at each level. The 3-pole design (3P) switches all three phases simultaneously; there is no switched neutral (neutral conductor switching is not fitted). This suits it for three-phase loads or as a feeder breaker where neutral is bonded elsewhere.

Combined terminals at both top and bottom accept standard copper conductors. The breaker is sealable — useful for utility or metering applications where tamper evidence is required.

The product designation (miniature circuit breaker) and the energy limitation class 3 indicate it limits let-through energy to protect downstream wiring. The product is suited for mechanical engineering and industry applications per the manufacturer's suitability classification.

Frequently asked questions

Where can I buy 5SY6302-6CC?

The 5SY6302-6CC is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of 5SY6302-6CC?

Rated breaking capacity is 6 kA per EN 60898 at AC 230/400 V, 50/60 Hz. This is the standard fault-interruption rating for this class of MCB.

Will 5SY6302-6CC drop into a panel specified for 5SY6332-7CC without rewiring?

Both are 3-pole SENTRON MCBs in the same 3-module-width footprint (54 mm wide, 76 mm deep), so the mechanical fit is identical. However, 5SY6332-7CC is a Type C 32 A breaker — verify that the 2 A Type B rating and the lower breaking capacity match your circuit protection requirements before substituting.

MPN
5SY6302-6CC