Skip to main content
Siemens 5SY6302-8CC — 3-Pole MCB (DIN Rail)

Siemens 5SY6302-8CC SENTRON MCB, 3P D 2A, 6kA

MPN5SY6302-8CC

Siemens SENTRON 5SY6302-8CC miniature circuit breaker, 3-pole, D tripping characteristic, 2 A rated current, 6 kA breaking capacity per EN 60898, 400 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY6302-8CC — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationMechanical engineering / industry
5SY6302-8CC — Protection
ParameterValue
Tripping characteristic (curve)D
Breaking capacity per EN 608986 kA
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Pollution degree3
5SY6302-8CC — Electrical
ParameterValue
Rated voltage (AC, multi-phase)440 V
Voltage type (AC/DC)AC
Supply frequency range50/60 Hz
Power loss per pole at rated current (AC, hot)1.2 W
Mechanical service life (operating cycles, typ.)10 000
Neutral conductor switchingNo
Rated voltage (AC, single-phase)440 V
5SY6302-8CC — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
Combined terminal, topYes
Combined terminal, bottomYes
Fastening methodQuick assembly system
SealableYes
Accepts supplementary devicesYes
5SY6302-8CC — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of surrounding temperaturemax. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
Vibration resistance (IEC 60068-2-6)±1mm at 5 to 25Hz; 50m/s² at 25 to 150Hz

Product details

Mounting position is any, which helps when the enclosure layout is tight.

Environmental and electrical ratings

Ambient temperature range is -40 °C to 75 °C, with humidity derating up to 95% at 55 °C, 55% at 70 °C, and 35% at 75 °C. Vibration resistance per IEC 60068-2-6 is ±1 mm at 5–25 Hz and 50 m/s² at 25–150 Hz, so it holds up on a machine frame or in a mobile installation.

Supplementary devices and approvals

The UL/CSA breaking capacity is 5 kA per UL 1077 and CSA C22.2 No. 235 — a step down from the IEC 6 kA, so check the label if the panel is destined for a North American job site.

Frequently asked questions

How do I get current pricing and availability for 5SY6302-8CC?

Submit an RFQ through this listing. The part is sourced to order through independent distribution; availability and current pricing are confirmed at quote time.

Will 5SY6302-8CC drop into a panel that was specified around 5SY4304-7CV without rewiring?

Both are 3-pole MCBs on a 54 mm wide DIN-rail footprint, so the mechanical fit is the same. The 5SY6302-8CC has a D-curve and 2 A rating; the 5SY4304-7CV is a C-curve at a different current. If the original panel was wired for a C-curve, the D-curve changes the trip coordination — check the load's inrush profile before swapping. No rewiring of the busbar or terminals is needed.

What compliance documentation does the brand provide for 5SY6302-8CC?

The part carries IEC 60898 ratings (6 kA breaking capacity) and UL 1077 / CSA C22.2 No. 235 ratings (5 kA). It is halogen-free and silicon-free, which supports RoHS and REACH compliance. The manufacturer provides a declaration of conformity and the relevant test certificates upon request.

MPN