Skip to main content
Siemens 5SY6304-6CC — 3-Pole MCB (DIN Rail)

Siemens 5SY6304-6CC SENTRON MCB, 3P B-Char 4A 6kA

MPN5SY6304-6CC

Siemens SENTRON 5SY6304-6CC, 3-pole miniature circuit breaker, B characteristic, 4 A rated current, 6 kA breaking capacity at 400 V AC, 50/60 Hz.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY6304-6CC — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Suitability for operationMechanical engineering / industry
5SY6304-6CC — Protection
ParameterValue
Tripping characteristic (curve)B
Breaking capacity per EN 608986 kA
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Energy limitation class3
Pollution degree3
5SY6304-6CC — Electrical
ParameterValue
Rated current (AC)400 V
Rated voltage (AC, multi-phase)440 V
5SY6304-6CC — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
Combined terminal, topYes
Combined terminal, bottomYes
Fastening methodQuick assembly system
SealableYes
5SY6304-6CC — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of surrounding temperaturemax. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C

Product details

The Siemens 5SY6304-6CC is a SENTRON miniature circuit breaker — 3-pole, B-trip characteristic, rated 4 A at 400 V AC, 50/60 Hz. IP20 with connected conductors — finger-safe terminals but not washdown-rated. Combined top and bottom terminals simplify daisy-chaining busbars.

Deployment context — panel integration and environmental range

The 5SY6304-6CC covers a wide ambient span: -40 °C to 75 °C, with humidity derating above 55 °C (95% RH to 55 °C, then 55% to 70 °C, 35% to 75 °C). That makes it usable in cold storage, outdoor cabinets, or near ovens — but the humidity curve means you don't seal the enclosure tight in high-temp, high-moisture zones without a breather. Vibration resistance per IEC 60068-2-6: ±1 mm at 5–25 Hz, 50 m/s² at 25–150 Hz. That's enough for general industrial machinery but not heavy rotating plant — if the panel mounts on a compressor skid, verify the vibration profile against that spec.

Frequently asked questions

What is the breaking capacity of the 5SY6304-6CC?

Rated 6 kA per EN 60898 at 400 V AC. That is the short-circuit interrupting rating at the terminals — match it to the available fault current at your panel.

Where can I buy the 5SY6304-6CC and get current pricing?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

Does the 5SY6304-6CC drop into a panel specified for the 5SY4140-7?

Both are 3-pole SENTRON MCBs on the same DIN-rail footprint, so the mechanical fit is the same. The 5SY6304-6CC carries a B-curve at 4 A / 6 kA; the 5SY4140-7 is a different rating and characteristic. Verify the branch-circuit protection requirements before substituting — the physical swap is straightforward, but the electrical coordination may differ.

MPN
5SY6304-6CC