Siemens 5SY6310-6 — Miniature Circuit Breakers (MCB)

Siemens 5SY6310-6 SENTRON MCB, 3-pole B-curve, 6kA/15kA

MPN5SY6310-6
Active

Siemens SENTRON 5SY6310-6 miniature circuit breaker, 3-pole, B-curve, 6 kA (EN 60898-1) / 15 kA (IEC 60947-2), 3-module width, IP20.

$25.40Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SY6310-6 — Ratings
ParameterValue
Overvoltage categoryIII
5SY6310-6 — Mechanical
ParameterValue
Width54 mm
Height90 mm
Depth76 mm

Product details

SENTRON 5SY6310-6 — panel-builder field note

The Siemens 5SY6310-6 is a 3-pole SENTRON miniature circuit breaker with B-curve tripping characteristic, rated 6 kA per EN 60898-1 and 15 kA per IEC 60947-2. At 400 V AC it handles the standard 50/60 Hz supply; the DC side is rated 15 kA at 60 V (max 72 V). This is a current-production part — no end-of-life notice on file — so it's a straightforward BOM line for new panels or replacement of an older 5SY-series MCB in the same footprint.

Breaking capacity — what the dual rating means

Two breaking-capacity numbers: 6 kA under EN 60898-1 (the household / commercial standard) and 15 kA under IEC 60947-2 (the industrial standard). The B-curve (3–5× In instantaneous trip) is standard for lighting and general-purpose loads, not motor starts. If your line uses this MCB for a motor branch, confirm the inrush won't nuisance-trip the B characteristic.

IP20 with conductors connected — fine for a closed panel, not for washdown zones.

Listed to IEC / EN 60898-1, IEC / EN 60947-2, and UL1077 / CSA C22.2 No.235 (5 kA at AC under UL). Halogen-free and silicon-free construction. The manufacturer provides a declaration of conformity covering RoHS and REACH; the standard IEC/EN ratings are printed on the nameplate for panel traceability.

Frequently asked questions

What is the breaking capacity of 5SY6310-6?

6 kA per EN 60898-1 and 15 kA per IEC 60947-2 at 400 V AC; at DC it is rated 15 kA at 60 V (max 72 V). Under UL1077 it is 5 kA at AC.

Will 5SY6310-6 drop into a panel specified for 5SY4140-7?

Both are 3-pole SENTRON MCBs in the same 3-module DIN-rail footprint, so the mechanical fit is the same. The 5SY6310-6 carries a B-curve; the 5SY4140-7 is a D-curve. If the panel was designed for a D-curve (motor or transformer loads), swapping to a B-curve may cause nuisance tripping on inrush. Check the load type before substituting.

Where can I buy 5SY6310-6 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.