Siemens 5SY6310-6 — 3-Pole MCB (DIN Rail)

Siemens 5SY6310-6 SENTRON MCB, 3-pole B-curve, 6kA/15kA

MPN5SY6310-6
Active

Siemens SENTRON 5SY6310-6 miniature circuit breaker, 3-pole, B-curve, 6 kA (EN 60898-1) / 15 kA (IEC 60947-2), 3-module width, IP20.

$25.40Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY6310-6 — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationMechanical engineering / industry
5SY6310-6 — Protection
ParameterValue
Tripping characteristic (curve)B
Breaking capacity per EN 608986 kA
Breaking capacity per IEC 60947-215 kA
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Energy limitation class3
Pollution degree3
5SY6310-6 — Electrical
ParameterValue
Rated voltage (AC, multi-phase)440 V
Voltage type (AC/DC)AC
Supply frequency range50/60 Hz
Power loss per pole at rated current (AC, hot)1.3 W
Mechanical service life (operating cycles, typ.)10 000
Neutral conductor switchingNo
Rated voltage (AC, single-phase)440 V
5SY6310-6 — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
Combined terminal, topYes
Combined terminal, bottomYes
Fastening methodQuick assembly system
SealableYes
Accepts supplementary devicesYes
5SY6310-6 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of surrounding temperaturemax. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
Vibration resistance (IEC 60068-2-6)±1mm at 5 to 25Hz; 50m/s² at 25 to 150Hz

Product details

SENTRON 5SY6310-6 — panel-builder field note

The Siemens 5SY6310-6 is a 3-pole SENTRON miniature circuit breaker with B-curve tripping characteristic, rated 6 kA per EN 60898-1 and 15 kA per IEC 60947-2. At 400 V AC it handles the standard 50/60 Hz supply; the DC side is rated 15 kA at 60 V (max 72 V). This is a current-production part — no end-of-life notice on file — so it's a straightforward BOM line for new panels or replacement of an older 5SY-series MCB in the same footprint.

Breaking capacity — what the dual rating means

Two breaking-capacity numbers: 6 kA under EN 60898-1 (the household / commercial standard) and 15 kA under IEC 60947-2 (the industrial standard). The B-curve (3–5× In instantaneous trip) is standard for lighting and general-purpose loads, not motor starts. If your line uses this MCB for a motor branch, confirm the inrush won't nuisance-trip the B characteristic.

IP20 with conductors connected — fine for a closed panel, not for washdown zones.

Listed to IEC / EN 60898-1, IEC / EN 60947-2, and UL1077 / CSA C22.2 No.235 (5 kA at AC under UL). Halogen-free and silicon-free construction. The manufacturer provides a declaration of conformity covering RoHS and REACH; the standard IEC/EN ratings are printed on the nameplate for panel traceability.

Frequently asked questions

What is the breaking capacity of 5SY6310-6?

6 kA per EN 60898-1 and 15 kA per IEC 60947-2 at 400 V AC; at DC it is rated 15 kA at 60 V (max 72 V). Under UL1077 it is 5 kA at AC.

Will 5SY6310-6 drop into a panel specified for 5SY4140-7?

Both are 3-pole SENTRON MCBs in the same 3-module DIN-rail footprint, so the mechanical fit is the same. The 5SY6310-6 carries a B-curve; the 5SY4140-7 is a D-curve. If the panel was designed for a D-curve (motor or transformer loads), swapping to a B-curve may cause nuisance tripping on inrush. Check the load type before substituting.

Where can I buy 5SY6310-6 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.