Skip to main content
Siemens 5SY6325-6 — Miniature Circuit Breakers (MCB)

Siemens SENTRON 5SY6325-6 Miniature Circuit Breaker, 3P B-Cu

MPN5SY6325-6
Active

Siemens SENTRON miniature circuit breaker, 3-pole, B-curve, 6 kA (EN 60898) / 15 kA (IEC 60947-2), 400 V AC, 60 V DC, IP20, halogen-free, silicon-free.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SY6325-6 — Ratings
ParameterValue
Overvoltage categoryIII
5SY6325-6 — Mechanical
ParameterValue
Width54 mm
Height90 mm
Depth76 mm

Product details

What it is and where it fits

The Siemens SENTRON 5SY6325-6 is a 3-pole miniature circuit breaker with B-curve tripping characteristic, designed to protect branch circuits in industrial control panels and distribution boards. It snaps onto a DIN rail (quick assembly system) and occupies 3 modular width units (54 mm). The IP20 rating with connected conductors means it's intended for enclosed panel mounting — not for wet or outdoor locations.

Key ratings and what they mean for your panel

Rated 6 kA per EN 60898-1 and 15 kA per IEC 60947-2 at 400 V AC. The higher IEC figure covers industrial installations where fault current may exceed the domestic EN rating — so this breaker can handle a 15 kA prospective short-circuit current without welding its contacts. For DC circuits, it's rated 15 kA at 60 V (max 72 V) per IEC 60947-2. Under UL 1077, the interrupting rating is 5 kA — that's the figure for North American supplemental protection applications. B-curve means the magnetic trip operates at 3 to 5 times rated current — typical for resistive and general-purpose loads where inrush isn't severe. Pollution degree 3 and overvoltage category III suit it for fixed industrial installations where transient overvoltages are common. The operating temperature range (-40 °C to 75 °C) covers cold storage and hot machine cabinets without derating.

Compliance and documentation

Certified to IEC/EN 60898-1, IEC/EN 60947-2, and UL 1077 — covers both IEC and North American supplemental protection. Halogen-free and silicon-free construction, sealable terminals, and a combined top/bottom terminal design for daisy-chaining. The manufacturer provides RoHS and REACH declarations as part of the standard documentation package.

Frequently asked questions

Where can I buy 5SY6325-6 and how do I get a price?

This part is sourced to order through independent distribution. Submit an RFQ for current pricing and availability — confirmed at quote time.

Will 5SY6325-6 drop into a panel that was specified around 5SY4304-7CV without rewiring?

Both are 3-pole SENTRON MCBs with the same DIN-rail footprint (3 modular widths, 54 mm). The 5SY6325-6 is a B-curve device; the 5SY4304-7CV is a different curve/rating variant. Mechanical fit is identical, but verify the trip characteristic and interrupting rating match your circuit design before swapping.

What compliance documentation does this brand provide for 5SY6325-6?

Standard documentation includes IEC/EN 60898-1, IEC/EN 60947-2, and UL 1077 certifications. RoHS and REACH declarations are available from the manufacturer.

MPN
5SY6325-6