Siemens 5SY6332-8CC SENTRON MCB, 32 A, D Curve, 6 kA, 3-Pole

MPN5SY6332-8CC

Siemens SENTRON 5SY6332-8CC, miniature circuit breaker, 3-pole, D characteristic, 32 A (35 °C), 6 kA (EN 60898), 440 V AC, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY6332-8CC — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationMechanical engineering / industry
5SY6332-8CC — Protection
ParameterValue
Tripping characteristic (curve)D
Breaking capacity per EN 608986 kA
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Pollution degree3
5SY6332-8CC — Electrical
ParameterValue
Rated voltage (AC, multi-phase)440 V
Voltage type (AC/DC)AC
Supply frequency range50/60 Hz
Power loss per pole at rated current (AC, hot)3.2 W
Neutral conductor switchingNo
Rated voltage (AC, single-phase)440 V
5SY6332-8CC — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
Combined terminal, topYes
Combined terminal, bottomYes
Fastening methodQuick assembly system
SealableYes
Accepts supplementary devicesYes
5SY6332-8CC — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of surrounding temperaturemax. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
Vibration resistance (IEC 60068-2-6)±1mm at 5 to 25Hz; 50m/s² at 25 to 150Hz

Product details

The Siemens SENTRON 5SY6332-8CC is a 3-pole miniature circuit breaker with a D tripping characteristic, rated 32 A at 35 °C and 440 V AC multi-phase. Per the datasheet, the D curve means it tolerates short-duration inrush currents up to 10–20× rated current — suited for motor-starting or transformer loads where a B or C curve would nuisance-trip. The interrupting capacity is 6 kA per EN 60898, adequate for most commercial and light industrial panelboards. Pollution degree 3 and overvoltage category III place it in fixed installations with conductive contamination possible.

Thermal derating and panel integration

The 5SY6332-8CC is rated 32 A at 35 °C, but the continuous current derates to 30.08 A at 40 °C, 29.09 A at 45 °C, 28.03 A at 50 °C, and 26.94 A at 55 °C. If the panel ambient runs above 35 °C — common in a sealed enclosure with other heat sources — the load must be reduced accordingly. The breaker occupies 3 modular width units (54 mm wide) and mounts in any position via the quick-assembly system. Depth is 76 mm with an installation depth of 70 mm; IP20 with connected conductors means it is protected against finger contact but not moisture, so keep it inside a rated enclosure. The combined terminal top and bottom accept both busbar and conductor connections.

Frequently asked questions

What is the interrupting capacity of 5SY6332-8CC?

Per EN 60898, the rated breaking capacity is 6 kA. That is the maximum prospective fault current the breaker can safely interrupt under standard test conditions.

Where can I buy 5SY6332-8CC and how is it quoted?

This part is sourced to order against an RFQ through independent distribution channels. Submit a request for quote to confirm current availability and pricing.