Siemens 5SY6340-8 — 3-Pole MCB (DIN Rail)

Siemens 5SY6340-8 SENTRON MCB, D-Curve 40A 3P 400V AC 6kA EN

MPN5SY6340-8

Siemens SENTRON 5SY6 series, D-curve miniature circuit breaker, 3-pole, 40 A, 400 V AC, 6 kA (EN 60898) / 10 kA (IEC 60947-2), 3 MW wide, IP20, snap-on DIN rail.

$110.74Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY6340-8 — Identification
ParameterValue
Design / model code5SY6
Brand nameSENTRON
Number of poles3
Suitability for operationMechanical engineering / industry
5SY6340-8 — Protection
ParameterValue
Tripping characteristic (curve)D
Breaking capacity per EN 608986 kA
Breaking capacity per IEC 60947-210 kA
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Pollution degree3
5SY6340-8 — Electrical
ParameterValue
Rated current (AC)400 V
Rated voltage (AC, multi-phase)440 V
Rated frequency50/60 Hz
5SY6340-8 — Mechanical
ParameterValue
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
Combined terminal, topYes
Combined terminal, bottomYes
SealableYes
5SY6340-8 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of surrounding temperaturemax. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C

Product details

SENTRON 5SY6340-8 — D-curve 40 A, 3-pole MCB for industrial branch circuits

Siemens SENTRON 5SY6 series miniature circuit breaker, D tripping characteristic, rated 40 A at 400 V AC, 3 poles. Occupies 3 width units (54 mm) on DIN rail. At DC, the IEC 60947-2 rating reaches 15 kA at 72 V. For UL 1077 / CSA C22.2 No. 235 applications, the interrupting rating is 5 kA. That spread means the same part covers IEC panels and UL-recognized supplementary protection — one BOM line for both regimes.

D-curve selectivity and coordination in the panel

The D-curve holds magnetic trip to 10–20× rated current (400–800 A instantaneous). That delay lets downstream motor-starting inrush pass without clearing the branch. Upstream, a higher-rated SENTRON or SITOR fuse must coordinate for full selectivity — typical rule: upstream device rated ≥ 1.6× the 40 A for overload discrimination, and the instantaneous thresholds must not overlap. The IP20 rating (with conductors connected) means it belongs inside a closed enclosure, not in washdown or outdoor exposure.

Mechanical integration — DIN rail, 3 MW, any position

Any mounting position is permitted — horizontal, vertical, or inverted — no derating required for orientation. The 54 mm width (3 module widths) matches the standard 18 mm/module grid; adjacent breakers or accessories (shunt trip, auxiliary switch) occupy adjacent slots without special spacing. Installation depth is 70 mm to the DIN rail surface; overall depth 76 mm includes the toggle and terminal screws. Ambient temperature range -40 °C to 75 °C, with derating for humidity: max 95% RH at 55 °C, 55% at 70 °C, 35% at 75 °C. That covers cold storage, unheated enclosures, and transformer cabinets.

MPN
5SY6340-8