Skip to main content
Siemens 5SY6363-7CC — 3-Pole MCB (DIN Rail)

Siemens 5SY6363-7CC SENTRON MCB, 3P C-Curve, 6 kA, 400 V

MPN5SY6363-7CC

Siemens SENTRON 5SY6363-7CC, 3-pole miniature circuit breaker, C-trip characteristic, 6 kA (EN 60898), 400 V AC, 72 V DC max, 3 MW units.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY6363-7CC — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationMechanical engineering / industry
5SY6363-7CC — Protection
ParameterValue
Tripping characteristic (curve)C
Breaking capacity per EN 608986 kA
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Energy limitation class3
Pollution degree3
5SY6363-7CC — Electrical
ParameterValue
Rated voltage (AC, multi-phase)440 V
Voltage type (AC/DC)AC
Supply frequency range50/60 Hz
Power loss per pole at rated current (AC, hot)4.8 W
Mechanical service life (operating cycles, typ.)10 000
Neutral conductor switchingNo
Rated voltage (AC, single-phase)440 V
5SY6363-7CC — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
Combined terminal, topYes
Combined terminal, bottomYes
Fastening methodQuick assembly system
SealableYes
Accepts supplementary devicesYes
5SY6363-7CC — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of surrounding temperaturemax. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
Vibration resistance (IEC 60068-2-6)±1mm at 5 to 25Hz; 50m/s² at 25 to 150Hz

Product details

Siemens SENTRON 5SY6363-7CC — 3-pole C-curve miniature circuit breaker

It is rated 6 kA breaking capacity per EN 60898 at 400 V AC, and carries a UL 1077 / CSA C22.2 No.235 rating of 5 kA for North American installations. Rated operating voltage is 400 V AC (440 V max single- or multi-phase), with a DC rating up to 72 V. Snap-on quick assembly and any mounting position simplify panel integration — no special orientation required.

Selection and coordination notes

The 6 kA rated short-circuit capacity per EN 60898 defines its fault-clearing capability at 400 V AC. For UL-listed panels, the 5 kA rating per UL 1077 applies — verify SCCR coordination with upstream protective devices. The C-trip characteristic is the key selection parameter: it allows short-duration inrush up to 10× rated current without nuisance tripping, making it the standard choice for motor control circuits, contactor coils, and lighting with electronic ballasts. If the load is purely resistive with no inrush, a B-curve MCB would provide faster fault response; if high inrush (transformers, large motors), a D-curve may be needed. The 5SY6363-7CC sits in the middle — the most common industrial choice.

Halogen-free and silicon-free construction reduces corrosive gas emission in a fault — important for panels housing sensitive electronics. Sealable to prevent unauthorized access to the trip setting or terminal area. Vibration resistance per IEC 60068-2-6: ±1 mm at 5–25 Hz, 50 m/s² at 25–150 Hz. Mechanical service life 10 000 operating cycles typical.

Frequently asked questions

Will 5SY6363-7CC drop into a panel specified for 5SY5240-7?

Both are 3-pole SENTRON MCBs on the same DIN-rail footprint and share the same 3-module width (54 mm). The 5SY6363-7CC carries a higher breaking capacity (6 kA vs the 5SY5240-7's rating) and the C-curve vs potentially a different characteristic on the 5SY5240-7. Physical fit is identical; verify the trip curve and breaking capacity match your panel's coordination study before swapping.

MPN
5SY6363-7CC