Siemens 5SY6403-6CC — 4-Pole MCB (DIN Rail)

Siemens 5SY6403-6CC SENTRON MCB, 4P, 3 A, B Curve, 6 kA

MPN5SY6403-6CC

Siemens SENTRON 5SY6403-6CC, 4-pole miniature circuit breaker, 3 A rated current, B tripping characteristic, 6 kA breaking capacity per EN 60898, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY6403-6CC — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY6403-6CC — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated current (In), AC3 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
5SY6403-6CC — Protection
ParameterValue
Tripping characteristic (trip curve)B
Rated breaking capacity (Icn), per EN 608986 kA
Energy limitation class3
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
Touch protectionYes
5SY6403-6CC — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY6403-6CC — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY6403-6CC — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

What this 4-pole MCB does on the line

The four poles (4P) switch all phases in a single module width of 4 modular units (72 mm wide), so it fits standard DIN-rail enclosures without extra bridging.

Thermal derating and environment

Rated 3 A at 35 °C ambient, the breaker derates to 2.82 A at 40 °C, 2.73 A at 45 °C, 2.63 A at 50 °C, and 2.53 A at 55 °C. If the panel runs warm — common in a crowded enclosure or near a freezer evaporator — size the load against the derated value at the actual ambient.

Depth is 76 mm, installation depth 70 mm, width 72 mm (4 MW), height 90 mm. The neutral is not switched (no neutral pole), so this breaker protects three phases plus a switched neutral? Check: the 4P designation here means all four poles are protected poles — verify the datasheet if you need a switched neutral.

Frequently asked questions

What is the depth of 5SY6403-6CC?

Depth is 76 mm, with an installation depth of 70 mm.