Siemens 5SY6406-6 — 4-Pole MCB (DIN Rail)

Siemens 5SY6406-6 SENTRON MCB, 4P, 6A, B-Curve, 6kA/30kA

MPN5SY6406-6
Active

Siemens SENTRON 5SY6 series, miniature circuit breaker, 4-pole, 6 A, B characteristic, 6 kA (EN 60898) / 30 kA (IEC 60947-2), 400 V AC, 4 width units.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY6406-6 — Identification
ParameterValue
Type / order code5SY6
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY6406-6 — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated current (In), AC400 V
Rated current (In), AC6 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
Rated voltage, DC (max.)72 V
Voltage typeAC
Rated frequency50/60 Hz
5SY6406-6 — Protection
ParameterValue
Tripping characteristic (trip curve)B
Rated breaking capacity (Icn), per EN 608986 kA
Rated breaking capacity, per IEC 60947-230 kA
Breaking capacity, AC (UL 1077 / CSA C22.2 No.235)5 kA
Overvoltage categoryIII
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingNo
Touch protectionYes
5SY6406-6 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
SealableYes
5SY6406-6 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY6406-6 — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

SENTRON 5SY6406-6 — 4-pole MCB, B-curve, 6 A

The Siemens 5SY6406-6 is a 4-pole miniature circuit breaker from the SENTRON 5SY6 series, rated 6 A at 400 V AC with a B tripping characteristic.

The B-curve trips at 3–5× rated current (18–30 A for this 6 A unit), so it's the right choice for resistive or general-purpose loads where inrush is modest — lighting, heaters, control transformers. Don't use it on motor circuits or high-inrush loads; that calls for a C or D curve. The 6 kA EN 60898 rating covers the standard domestic/commercial fault level; the 30 kA IEC 60947-2 rating confirms it can be applied in industrial panels with higher prospective fault current, as long as the installation complies with the industrial standard. Four poles (4P) means it switches and protects all three phases plus neutral. The neutral pole is switched but not inherently protected — confirm the neutral arrangement in your distribution board before specifying.

Mount in any position; ambient range -25 to +55 °C.

Frequently asked questions

Where can I buy the 5SY6406-6 and get a price?

This part is sourced and quoted to order against an RFQ. Submit a request through the storefront; availability and current pricing are confirmed at quote time.

What is the breaking capacity of the 5SY6406-6 under IEC 60947-2?

30 kA at 400 V AC per IEC 60947-2, which qualifies it for industrial panels with higher prospective fault current. The EN 60898 rating is 6 kA.

What wire sizes does the 5SY6406-6 accept?

Solid or stranded copper from 0.75 mm² up to 35 mm² at both the top and bottom combined terminals.

MPN
5SY6406-6