Skip to main content
Siemens 5SY6416-7CC — 4-Pole MCB (DIN Rail)

Siemens 5SY6416-7CC SENTRON MCB, 4P C16 6kA, 440V AC

MPN5SY6416-7CC

Siemens SENTRON miniature circuit breaker, 5SY6416-7CC, 4-pole, C tripping characteristic, 16 A rated current, 6 kA breaking capacity per EN 60898, 440 V AC, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY6416-7CC — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY6416-7CC — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated voltage, AC (multi-phase)440 V
5SY6416-7CC — Protection
ParameterValue
Tripping characteristic (trip curve)C
Energy limitation class3
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
5SY6416-7CC — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY6416-7CC — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY6416-7CC — Performance
ParameterValue
Power loss per pole, AC (hot state, at In)1.8 W

Product details

Siemens SENTRON 5SY6416-7CC — 4-pole C16 MCB for panel builds

The Siemens 5SY6416-7CC is a 4-pole miniature circuit breaker from the SENTRON series, rated 16 A with a C tripping characteristic and a 6 kA breaking capacity. It operates on 440 V AC at 50/60 Hz. The C-curve (tripping between 5 and 10 times rated current) suits it for moderate inrush loads like small motors, transformers, and banks of contactor coils — common in mechanical engineering and industrial applications.

What the ratings mean for fit

The 6 kA breaking capacity covers the majority of domestic and light industrial installations where the prospective short-circuit current stays under that threshold. Overvoltage category III and pollution degree 3 confirm it is rated for fixed installations inside a panel or enclosure. Temperature derating is built into the spec: at 40 °C the continuous current is 15.04 A, dropping to 14.02 A at 50 °C and 13.47 A at 55 °C. If the panel ambient runs hot, size the upstream protection accordingly — the 16 A nameplate rating is only valid at 35 °C. The 4-pole design (4P) switches all phases but does not switch the neutral — confirmed by the neutral conductor switching field set to No. That is typical for TN systems where the neutral is bonded at the source and does not require overcurrent protection.

Panel integration and mounting

Snaps onto DIN rail via the quick assembly system, occupying 4 modular width units (72 mm wide). Mounting position is any, which simplifies layout in crowded enclosures. Installation depth is 70 mm behind the panel face; overall depth is 76 mm. Combined terminals at both top and bottom accept the same conductor range, so line and load can be wired from either direction. The unit is sealable, halogen-free, and silicon-free — relevant for clean-room or food-production environments where outgassing must be controlled. IP20 protection with connected conductors means it is touch-safe once wired but not rated for washdown or outdoor exposure — keep it inside a locked enclosure rated to at least IP54.

MPN