Skip to main content
Siemens 5SY6432-6 — 4-Pole MCB (DIN Rail)

Siemens 5SY6432-6 SENTRON MCB, 4P B-Curve, 6kA IEC/EN 60898-

MPN5SY6432-6
Active

Siemens SENTRON 5SY6432-6, 4-pole miniature circuit breaker, B-curve, 6 kA (IEC/EN 60898-1) / 15 kA (IEC 60947-2), 400 V AC, 72 mm wide, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY6432-6 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY6432-6 — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated voltage, AC (multi-phase)440 V
5SY6432-6 — Protection
ParameterValue
Tripping characteristic (trip curve)B
Energy limitation class3
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
5SY6432-6 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY6432-6 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY6432-6 — Performance
ParameterValue
Power loss per pole, AC (hot state, at In)2.6 W

Product details

The Siemens 5SY6432-6 is a 4-pole SENTRON miniature circuit breaker with a B-curve trip characteristic, rated 6 kA breaking capacity per IEC/EN 60898-1 and 15 kA per IEC 60947-2 at 400 V AC. The IP20 enclosure (with conductors connected) suits clean, dry panel environments — typical for distribution boards and control cabinets in mechanical engineering and industrial settings.

Breaking capacity and dual standard rating

The 6 kA rating under IEC/EN 60898-1 covers residential and light commercial branch circuits. The 15 kA rating under IEC 60947-2 (and matching 15 kA at DC) means this breaker also qualifies for industrial panel SCCR requirements where higher fault currents are expected. That dual rating is the main reason to reach for this over a standard 6 kA-only MCB — it gives you headroom without swapping to a larger frame.

Integration notes

The quick-assembly fastening method and combined top/bottom terminals speed wiring. Sealable design allows lockout/tagout.

Frequently asked questions

How do I get current pricing and availability for 5SY6432-6?

Pricing and stock are confirmed at quote time. Submit an RFQ through this listing; we source the part to order via independent distribution and respond with current availability and a firm price.

What is the breaking capacity of 5SY6432-6?

6 kA per IEC/EN 60898-1 and 15 kA per IEC 60947-2 at 400 V AC. At DC (per IEC 60947-2) it is also rated 15 kA. Under UL 1077 / CSA C22.2 No.235 it carries 5 kA.

What compliance documentation does Siemens provide for 5SY6432-6?

The breaker is certified to IEC / EN 60898-1, IEC / EN 60947-2, and UL 1077 / CSA C22.2 No.235. It is halogen-free and silicon-free. Standard documentation includes the declaration of conformity and the datasheet.

MPN
5SY6432-6