Siemens 5SY6440-7CC — 4-Pole MCB (DIN Rail)

Siemens 5SY6440-7CC SENTRON MCB, 4P C-40A 6kA

MPN5SY6440-7CC

Siemens SENTRON 5SY6440-7CC, 4-pole miniature circuit breaker, C-curve, 40 A rated at 35 °C, 6 kA breaking capacity per EN 60898, IP20, halogen-free, silicon-free.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY6440-7CC — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY6440-7CC — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated voltage, AC (multi-phase)440 V
5SY6440-7CC — Protection
ParameterValue
Tripping characteristic (trip curve)C
Energy limitation class3
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
5SY6440-7CC — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY6440-7CC — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY6440-7CC — Performance
ParameterValue
Power loss per pole, AC (hot state, at In)3.5 W

Product details

SENTRON 5SY6440-7CC — 4-Pole C-Curve MCB at 40 A

The Siemens SENTRON 5SY6440-7CC is a 4-pole miniature circuit breaker with a C-tripping characteristic, rated 40 A at 35 °C and providing a 6 kA breaking capacity certified to EN 60898. This is the part for a 3-phase plus neutral branch circuit where the load is moderate-inrush — motors, transformers, or groups of LED drivers — and the fault current at the panel does not exceed 6 kA.

The 40 A rating is valid at 35 °C ambient. At 40 °C the continuous current drops to 38.12 A; at 45 °C to 37.12 A; at 50 °C to 36.12 A; and at 55 °C to 35.08 A. The operating range spans -40 °C to 75 °C, with humidity limits of 95% up to 55 °C, 55% up to 70 °C, and 35% at 75 °C.

The combined terminal at both top and bottom accepts the same conductor range, so wiring order is reversible.

Compliance and Material Declarations

Halogen-free and silicon-free construction is declared, which matters for outgassing-sensitive environments such as clean rooms, medical equipment, or aerospace panels where silicone contamination can inhibit relay contacts. The MCB is sealable — a lead seal can be fitted through the housing to prevent tampering in metered or safety-critical circuits. Energy limitation class 3 is assigned per EN 60898, meaning the let-through energy under fault is low enough to protect downstream wiring without cascading damage.

Frequently asked questions

What is the breaking capacity of 5SY6440-7CC?

6 kA per EN 60898. This is sufficient for most commercial and light-industrial sub-distribution boards where the prospective short-circuit current at the breaker is under 6 kA.

What compliance documentation does Siemens provide for 5SY6440-7CC?

The MCB carries declarations for halogen-free and silicon-free construction, and is certified to EN 60898. Pollution degree 3 and overvoltage category III are declared, meeting the requirements for fixed industrial installations. Full RoHS and REACH declarations are available from Siemens on request.

Where can I buy 5SY6440-7CC and what is the lead time?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm lead time.

MPN