Skip to main content
Siemens 5SY6502-7 — 1-Pole MCB (DIN Rail)

Siemens 5SY6502-7 SENTRON MCB, 2-pole C-curve, 6 kA IEC/EN 6

MPN5SY6502-7
Active

Siemens SENTRON 5SY6502-7 miniature circuit breaker, 2-pole (1P+N), C-curve, 6 kA breaking capacity per EN 60898-1, 30 kA per IEC 60947-2.

$15.24Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY6502-7 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles2
Pole design1P+N
Application suitabilityMechanical engineering / industry
5SY6502-7 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Energy limitation class3
Overvoltage categoryIII
5SY6502-7 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units2
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY6502-7 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

It carries a 6 kA rated breaking capacity under EN 60898-1 for domestic/commercial branch circuits, and a 30 kA rating under IEC 60947-2 for industrial panel applications where higher fault current is expected. That dual rating lets you use the same breaker across different installation environments without swapping part numbers.

Sourcing and fit

The quick-assembly fastening method and combined top/bottom terminals mean it snaps onto the DIN rail and accepts busbar plug-in feeders without extra wiring — a time-saver on repetitive panel builds. For a BOM line that requires a 2-pole C-curve MCB with dual breaking capacity ratings, this part is a direct fit. No adapter or cross-reference needed. The neutral conductor switching is built in, so you don't need a separate switched-neutral accessory.

Frequently asked questions

What are the key breaking capacity ratings?

6 kA per EN 60898-1 for household-type branch circuits, and 30 kA per IEC 60947-2 for industrial panel applications. Under UL 1077 it is rated 5 kA.

What compliance documentation is available?

The breaker is certified to IEC/EN 60898-1, IEC/EN 60947-2, and UL 1077. It is halogen-free and silicon-free. Standard manufacturer declarations for CE, UKCA, and RoHS are provided with the shipment.

What are the physical dimensions?

Width 36 mm — 2 modular units; depth 76 mm; height 90 mm; installation depth 70 mm. Fits standard DIN-rail enclosures.

MPN
5SY6502-7