Siemens 5SY6506-6 — 1-Pole MCB (DIN Rail)

Siemens 5SY6506-6 SENTRON MCB, 1P+N, B-Curve, 6kA/30kA

MPN5SY6506-6
Active

Siemens SENTRON 5SY6506-6, miniature circuit breaker, 1P+N, B tripping characteristic, 6 kA per EN 60898, 30 kA per IEC 60947-2, 2 MW units wide.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY6506-6 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles2
Pole design1P+N
Application suitabilityMechanical engineering / industry
5SY6506-6 — Electrical & Protection
ParameterValue
Tripping characteristic classB
Energy limitation class3
Overvoltage categoryIII
5SY6506-6 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units2
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY6506-6 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

Dual-standard breaking capacity — what it means for panel design

The 5SY6506-6 carries both IEC/EN 60898-1 (6 kA) and IEC/EN 60947-2 (30 kA) ratings, plus UL 1077 and CSA C22.2 No. 235 (5 kA). This is the same dual-certification approach as the 5SL series, but the 5SY family adds a neutral-switching pole (1P+N) that the 5SL single-pole breakers lack. If your panel spec calls for disconnecting the neutral on a single-phase circuit, the 5SY6506-6 fits where a 5SL6006-7 would not.

Panel integration — dimensions and mounting

Snap-on mounting to DIN rail (EN 60715). Mounting position is any — horizontal, vertical, or flat — no derating required.

Frequently asked questions

Will 5SY6506-6 drop into a panel specified around 5SY4140-7 without rewiring?

Both are 2-MW-unit SENTRON breakers with the same 36 mm width and DIN-rail mounting, so the mechanical fit is identical. The key difference is tripping characteristic: 5SY6506-6 is B-curve, while 5SY4140-7 is a different curve — verify the coordination study before swapping. The terminal layout and busbar pitch are the same.