Skip to main content
Siemens 5SY6506-7CC — 1-Pole MCB (DIN Rail)

Siemens 5SY6506-7CC SENTRON MCB, C-Curve, 2-Pole 1P+N, 6kA

MPN5SY6506-7CC

Siemens SENTRON, miniature circuit breaker, 5SY6506-7CC, C characteristic, 2-pole (1P+N), 6 kA at 230 V AC per EN 60898, 36 mm width, 76 mm depth.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY6506-7CC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles2
Pole design1P+N
Application suitabilityMechanical engineering / industry
5SY6506-7CC — Electrical & Protection
ParameterValue
Tripping characteristic classC
Energy limitation class3
Overvoltage categoryIII
5SY6506-7CC — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units2
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY6506-7CC — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

The 6 kA breaking capacity at 230 V AC (per EN 60898) covers most commercial and light industrial panel fault levels; for UL 1077 / CSA C22.2 No.235 installations the rating is 5 kA. The neutral conductor is switched, so this breaker fully isolates the downstream circuit on overcurrent or manual opening — important for maintenance isolation on single-phase sub-circuits.

At 36 mm wide (2 modular width units) and 76 mm deep, this breaker occupies two standard DIN-rail slots. Mounting position is unrestricted, so it can be installed horizontally or inverted if panel layout demands it. The quick-assembly fastening system clips onto the DIN rail without tools and releases via a screwdriver slot. IP20 with connected conductors is the standard for enclosed distribution boards; no special sealing is needed inside a rated panel.

Environmental and mechanical margins

Rated for ambient temperatures from -40 °C to 75 °C, with derating above 55 °C: max 95% humidity up to 55 °C, dropping to 55% at 70 °C and 35% at 75 °C. The 10 000 mechanical operating cycles typical cover decades of occasional switching in a distribution board. Vibration resistance per IEC 60068-2-6 (±1 mm at 5–25 Hz, 50 m/s² at 25–150 Hz) confirms suitability for installation near rotating machinery or on factory walls subject to low-frequency vibration.

Supplementary devices and power loss

Power loss is 1.2 W per pole at rated current in hot operating state, so a 2-pole unit dissipates 2.4 W total. In a densely populated enclosure with many breakers, that heat adds up; plan ventilation or de-rate if ambient inside the panel exceeds 55 °C.

Frequently asked questions

Where can I buy 5SY6506-7CC and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead-time estimate.

What is 5SY6506-7CC's listed depth (76 mm) on this component line?

The depth is 76 mm, with an installation depth of 70 mm — the extra 6 mm accounts for the terminal screws and busbar connection overhang.

What is 5SY6506-7CC's listed width (36 mm) on this component line?

The width is 36 mm, which equals 2 modular width units on a standard DIN-rail panel.

Will 5SY6506-7CC drop into a panel that was specified around 5SY4101-7CV without rewiring?

Both are 2-module-wide SENTRON MCBs on the same DIN-rail footprint, so the mechanical fit is identical. The 5SY6506-7CC is a C-curve 1P+N breaker with neutral switching; the 5SY4101-7CV is a different rating/curve variant. If the panel wiring was designed for a 1P+N configuration with switched neutral, the 5SY6506-7CC drops in without rewiring — but verify the rated current and breaking capacity match the circuit design.

What compliance documentation does this brand provide for 5SY6506-7CC (RoHS, REACH, UL, IEC)?

The breaker is rated per EN 60898 at 6 kA and per UL 1077 / CSA C22.2 No.235 at 5 kA. Halogen-free and silicon-free construction supports RoHS/REACH compliance. Standard Siemens SENTRON documentation includes the EC Declaration of Conformity and the UL/CSA file; request specific certificates with your RFQ.

MPN