Siemens 5SY6506-8 — 1-Pole MCB (DIN Rail)

Siemens 5SY6506-8 SENTRON MCB, 6A D-curve, 2-pole 1P+N, 30kA

MPN5SY6506-8

Siemens SENTRON 5SY6506-8, miniature circuit breaker, 2-pole 1P+N, 6 A rated, D tripping characteristic, 30 kA IEC 60947-2, 6 kA EN 60898.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY6506-8 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles2
Application suitabilityMechanical engineering / industry
5SY6506-8 — Electrical & Protection
ParameterValue
Tripping characteristic classD
Rated value (EN 60898)6 kA
Overvoltage categoryIII
5SY6506-8 — Mounting & Connection
ParameterValue
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
SealableYes
5SY6506-8 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Halogen-freeYes
Silicone-freeYes

Product details

Siemens SENTRON 5SY6506-8 — 6 A D-curve MCB, 2-pole 1P+N

The 1P+N pole configuration switches the live conductor and provides a switched neutral, suitable for single-phase AC circuits up to 230 V. At 6 A, this handles sustained loads up to 1.38 kW on a 230 V line, with the magnetic trip clearing short-circuit faults before the thermal element sees them.

For DC circuits, the IEC 60947-2 rating is 15 kA at 72 V DC maximum. Under UL 1077 (supplementary protector listing), it carries 5 kA at 230 V AC. Overvoltage category III (OVC III) means it's rated for fixed-installation distribution boards, not just socket-outlet circuits. The 1P+N configuration with switched neutral is common in IEC markets where the neutral is not distributed as a protected pole — verify the panel's neutral bus arrangement before specifying.

That's a wide range — fine for control-circuit tails (1.5 mm²) up to main feeder taps (10 mm² or 16 mm²). Touch protection is built into the terminal design (IP20 with connected conductors). Sealable terminals allow the panel builder to lock the cover screws after commissioning — useful for installations where tamper-proofing is required.

Environmental range and lifecycle

Designed for mechanical engineering and industrial applications per the manufacturer's suitability listing. The 5SY6 series is the standard industrial MCB line within the SENTRON portfolio, positioned between the domestic 5SL series and the high-performance 5SY7 range.

Frequently asked questions

What is the breaking capacity of 5SY6506-8 under IEC 60947-2?

30 kA at 230 V AC per IEC 60947-2. Under EN 60898 it is 6 kA, and under UL 1077 it is 5 kA. For DC circuits, the IEC 60947-2 rating is 15 kA at 72 V DC maximum.

What wire sizes does the 5SY6506-8 accept?

Combined terminals accept solid or stranded conductors from 0.75 mm² up to 35 mm². The terminals are sealable and include touch protection.

Will 5SY6506-8 drop into a panel specified around 5SY4140-7 without rewiring?

Both are 2-pole 1P+N MCBs on a 36 mm (2 width units) footprint, so the DIN rail position and busbar spacing are identical. The terminal range (0.75–35 mm²) is the same. The key difference is the tripping characteristic: 5SY6506-8 is D-curve (10–20× In), while 5SY4140-7 is a different curve — check the existing panel's coordination study before swapping.

How do I get current pricing and availability for 5SY6506-8?

Sourced to order against an RFQ through independent distribution. Submit a request for quote (RFQ) with your quantity and target delivery window; availability and current pricing are confirmed at quote time.