Skip to main content
Siemens 5SY6508-8 — 1-Pole MCB (DIN Rail)

Siemens 5SY6508-8 SENTRON MCB, 2-pole D-curve 8A, 6kA/15kA

MPN5SY6508-8

Siemens SENTRON 5SY6 series, miniature circuit breaker, 2-pole (1P+N), 8 A, D tripping characteristic, 230 V AC, 6 kA / 15 kA breaking capacity.

$72.01Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY6508-8 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles2
Application suitabilityMechanical engineering / industry
5SY6508-8 — Electrical & Protection
ParameterValue
Tripping characteristic classD
Rated value (EN 60898)6 kA
Overvoltage categoryIII
5SY6508-8 — Mounting & Connection
ParameterValue
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
SealableYes
5SY6508-8 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens 5SY6508-8 is a SENTRON 5SY6 miniature circuit breaker — 2-pole (1P+N), rated 8 A at 230 V AC with a D tripping curve. The 6 kA breaking capacity per EN 60898 covers most sub-distribution boards, and the 15 kA rating per IEC 60947-2 gives headroom for industrial panel feeders where fault current runs higher. It mounts on a DIN rail via the quick-assembly system, snaps into two width units (36 mm), and accepts solid or stranded conductors from 0.75 mm² up to 35 mm² at the combined top and bottom terminals.

Deployment context and environmental limits

Rated for ambient temperatures from -25 °C to +55 °C, with storage range from -40 °C to +75 °C — fine for unheated enclosures in temperate climates.

Rated per EN 60898 at 6 kA and per IEC 60947-2 at 15 kA (both AC and DC). Also carries a UL 1077 / CSA C22.2 No. 235 rating at 5 kA, which covers North American supplementary protection applications. Touch protection is built in.

Frequently asked questions

What is the breaking capacity of the 5SY6508-8?

6 kA per EN 60898 and 15 kA per IEC 60947-2 at 230 V AC; also rated 15 kA DC per IEC 60947-2, and 5 kA per UL 1077 / CSA C22.2 No. 235.

Where can I buy the 5SY6508-8?

We source and quote it to order against an RFQ through our independent distribution channel. Submit your request and we'll confirm availability and current pricing at quote time.

What wire sizes does the 5SY6508-8 accept?

Solid and stranded conductors from 0.75 mm² up to 35 mm², at both top and bottom combined terminals.

MPN
5SY6508-8