Skip to main content
Siemens 5SY6516-7CC — 1-Pole MCB (DIN Rail)

Siemens 5SY6516-7CC SENTRON MCB, C-16A, 6kA, 2-Pole

MPN5SY6516-7CC

Siemens SENTRON 5SY6 series miniature circuit breaker, order code 5SY6516-7CC, C-tripping characteristic, 16 A rated current, 6 kA breaking capacity per EN 60898, 2-pole (1P+N), 36 mm width.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY6516-7CC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles2
Pole design1P+N
Application suitabilityMechanical engineering / industry
5SY6516-7CC — Electrical & Protection
ParameterValue
Tripping characteristic classC
Energy limitation class3
Overvoltage categoryIII
5SY6516-7CC — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units2
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY6516-7CC — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens 5SY6516-7CC is a SENTRON miniature circuit breaker (MCB) with a C-tripping characteristic, rated 16 A at 35 °C and breaking 6 kA per EN 60898. It's a 2-pole unit in a 1P+N design — meaning it switches both the line and neutral conductors, with the neutral pole switching but not protected. That makes it the right choice for single-phase final circuits where you need to isolate the neutral, common in distribution boards across mechanical engineering and industrial panels.

The C-curve (tripping characteristic class C) means the magnetic trip operates at 5 to 10 times the rated current — so for this 16 A MCB, instantaneous trip happens between 80 A and 160 A. Temperature derating is built into the spec: it carries the full 16 A up to 35 °C, then drops to 15.04 A at 40 °C, 14.54 A at 45 °C, 14.02 A at 50 °C, and 13.47 A at 55 °C.

Mounting and integration notes

Accepts any mounting position.

Frequently asked questions

What are the key ratings for the 5SY6516-7CC?

Rated current 16 A at 35 °C, C-tripping characteristic, 6 kA breaking capacity per EN 60898, 2-pole 1P+N design, operating voltage AC 50/60 Hz, maximum DC operating voltage 72 V.

What is the physical size of the 5SY6516-7CC?

Width 36 mm (2 modular units), height 90 mm, depth 76 mm, installation depth 70 mm. It snaps onto standard DIN rail.

Where can I buy the 5SY6516-7CC?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment.

How does the 5SY6516-7CC compare to the 5SY4116-6CC?

The 5SY4116-6CC is a different series within the SENTRON family — typically a 1-pole unit with a B-curve, while the 5SY6516-7CC is a 2-pole (1P+N) C-curve. They share the same 16 A rating and 6 kA breaking capacity, but the pole count and tripping curve differ. The 5SY6516-7CC will not drop into a panel wired for a single-pole B-curve MCB without rewiring the neutral and checking the trip coordination.

MPN
5SY6516-7CC