Skip to main content
Siemens 5SY6520-8 — 1-Pole MCB (DIN Rail)

Siemens 5SY6520-8 SENTRON MCB, 2-pole 20A D-curve, 6/15 kA

MPN5SY6520-8

Siemens SENTRON 5SY6 series, miniature circuit breaker, 2-pole 1P+N, 20 A, D tripping characteristic, 6 kA per EN 60898 / 15 kA per IEC 60947-2, 230 V AC, 2 MW.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY6520-8 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles2
Application suitabilityMechanical engineering / industry
5SY6520-8 — Electrical & Protection
ParameterValue
Tripping characteristic classD
Rated value (EN 60898)6 kA
Overvoltage categoryIII
5SY6520-8 — Mounting & Connection
ParameterValue
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
SealableYes
5SY6520-8 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens 5SY6520-8 is a 2-pole (1P+N) SENTRON miniature circuit breaker rated 20 A with a D tripping characteristic, designed to handle high inrush currents typical of motor and transformer loads. Its 6 kA breaking capacity per EN 60898 covers most residential and light commercial panels, while the 15 kA rating per IEC 60947-2 gives headroom for industrial distribution boards with higher fault currents. The D-curve means the magnetic trip activates at 10–20× In, so it won't nuisance-trip on motor start-up. The terminals accept solid or stranded conductors from 0.75 to 35 mm², and the combined top/bottom terminals simplify daisy-chaining in a distribution board.

Rated for 230 V AC, overvoltage category III. Breaking capacities are certified per EN 60898 (6 kA) and IEC 60947-2 (15 kA), with a DC rating of 15 kA per IEC 60947-2 up to 72 V DC. Also carries a 5 kA rating per UL 1077 and CSA C22.2 No. 235 for North American panels. Halogen-free and silicon-free construction, touch protection integrated.

Frequently asked questions

How do I get current pricing and availability for 5SY6520-8?

Submit an RFQ through this listing. Pricing and stock are confirmed at quote time — no fixed online price is published.

What is the breaking capacity of 5SY6520-8?

6 kA per EN 60898 and 15 kA per IEC 60947-2 at 230 V AC, plus 15 kA DC per IEC 60947-2 up to 72 V DC. For UL/CSA applications, it is rated 5 kA.

What conductor sizes does the 5SY6520-8 accept?

Solid and stranded conductors from 0.75 to 35 mm² fit the combined top and bottom terminals.

MPN