Skip to main content
Siemens 5SY6550-8CC — 1-Pole MCB (DIN Rail)

Siemens 5SY6550-8CC SENTRON MCB, 1P+N, D Curve, 50 A, 6 kA

MPN5SY6550-8CC

Siemens SENTRON 5SY6550-8CC, miniature circuit breaker, 1P+N, D characteristic, 50 A, 6 kA per EN 60898, 230 V AC, 2 MW width.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY6550-8CC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles2
Pole design1P+N
Application suitabilityMechanical engineering / industry
5SY6550-8CC — Electrical & Protection
ParameterValue
Tripping characteristic classD
Overvoltage categoryIII
5SY6550-8CC — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units2
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY6550-8CC — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

The 5SY6550-8CC is a Siemens SENTRON miniature circuit breaker rated 50 A with a D tripping characteristic, 1-pole plus switched neutral (1P+N), and a 6 kA breaking capacity per EN 60898 at 230 V AC. The 2 MW width (36 mm) occupies two standard DIN-rail positions, and the neutral pole switches simultaneously with the line pole, so it isolates both conductors on a single-phase circuit — no separate neutral bar needed downstream.

Deployment context

The IP20 rating applies only with connected conductors — the breaker itself is open-frame, intended inside a closed enclosure. Suitability marked for mechanical engineering and industrial environments, which matches the D-curve application: conveyors, pumps, compressors, and machine-tool circuits where the load draws a high starting surge. The 50 A rating at 230 V AC covers a single-phase branch up to roughly 11.5 kW resistive or a motor load sized within the D-curve's inrush envelope.

Compliance and approvals

The breaker carries a 6 kA breaking capacity per EN 60898 and a 5 kA rating per UL 1077 and CSA C22.2 No. 235, so it is accepted in both IEC and North American control-circuit applications (though not as a branch-circuit protective device under UL 489). Vibration resistance per IEC 60068-2-6 covers ±1 mm at 5–25 Hz and 50 m/s² at 25–150 Hz — enough for machine-mounted panels near moderate vibration sources.

Frequently asked questions

Where can I buy 5SY6550-8CC and how do I get a price?

The 5SY6550-8CC is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer.

What is 5SY6550-8CC's listed depth (76 mm) on this component line?

The 5SY6550-8CC has a depth of 76 mm, a width of 36 mm (2 MW), and a height of 90 mm. Installation depth is 70 mm, matching standard DIN-rail enclosures.

Will 5SY6550-8CC drop into a panel that was specified around 5SY6332-7CC without rewiring?

Both are 2 MW wide SENTRON 5SY series breakers on the same DIN footprint, so the 5SY6550-8CC will physically fit the same rail and busbar position. However, the 5SY6332-7CC is a 32 A C-curve device; the 5SY6550-8CC is a 50 A D-curve. Verify that the branch circuit's conductor sizing, upstream protection, and load inrush characteristic match the D curve's higher magnetic trip threshold before substitution.

What compliance documentation does this brand provide for 5SY6550-8CC (RoHS, REACH, UL, IEC)?

The 5SY6550-8CC is certified to EN 60898 (6 kA), UL 1077 and CSA C22.2 No. 235 (5 kA), and is halogen-free and silicon-free. Overvoltage category III and pollution degree 3 are marked. RoHS and REACH declarations are standard from Siemens for SENTRON products — request them with the order.

MPN
5SY6550-8CC