Siemens 5SY6563-7CC — 1-Pole MCB (DIN Rail)

Siemens 5SY6563-7CC SENTRON MCB, C-curve 63 A 6 kA

MPN5SY6563-7CC

Siemens SENTRON 5SY6563-7CC, miniature circuit breaker, 2-pole 1P+N, C-curve, 63 A rated at AC, 6 kA breaking capacity per EN 60898, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY6563-7CC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles2
Pole design1P+N
Application suitabilityMechanical engineering / industry
5SY6563-7CC — Electrical & Protection
ParameterValue
Tripping characteristic classC
Rated value (EN 60898)6 kA
Energy limitation class3
Overvoltage categoryIII
5SY6563-7CC — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units2
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY6563-7CC — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens SENTRON 5SY6563-7CC is a 2-pole (1P+N) miniature circuit breaker with a C-curve tripping characteristic, rated 63 A at AC and a 6 kA breaking capacity per EN 60898. The 6 kA rating at 400 V is the standard for most commercial and light industrial distribution boards; for UL-tracked jobs, it carries a 5 kA interrupting rating per UL 1077 and CSA C22.2 No.235.

The combined terminal design (top and bottom) accepts standard screw-clamp wiring; touch protection is built in.

Thermal derating and environmental range

The 63 A rating holds at 35 °C ambient. At 40 °C it derates to 60.04 A; at 50 °C to 56.89 A; at 55 °C to 55.25 A. Operating range spans -40 °C to 75 °C, with humidity limits of 95% up to 55 °C, 55% up to 70 °C, and 35% at 75 °C. Vibration resistance per IEC 60068-2-6 covers ±1 mm at 5–25 Hz and 50 m/s² at 25–150 Hz — adequate for machine-mounted panels on pumps or conveyors.

Frequently asked questions

What is the breaking capacity of 5SY6563-7CC?

6 kA per EN 60898 at 400 V AC, and 5 kA per UL 1077 and CSA C22.2 No.235 — adequate for most commercial and light industrial panelboards.