Skip to main content
Siemens 5SY6601-7 — 4-Pole MCB (DIN Rail)

Siemens 5SY6601-7 SENTRON MCB, 4P C 1A, 6kA/30kA

MPN5SY6601-7
Active

Siemens SENTRON miniature circuit breaker, 5SY6601-7, 4-pole (3P+N), C characteristic, 1 A rated, 6 kA (EN 60898) / 30 kA (IEC 60947-2) breaking capacity.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY6601-7 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY6601-7 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated current (In), AC1 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
5SY6601-7 — Protection
ParameterValue
Tripping characteristic (trip curve)C
Rated breaking capacity (Icn), per EN 608986 kA
Rated breaking capacity, per IEC 60947-230 kA
Breaking capacity, AC (UL 1077 / CSA C22.2 No.235)5 kA
Energy limitation class3
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
Touch protectionYes
5SY6601-7 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY6601-7 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY6601-7 — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

Siemens 5SY6601-7 — 4-Pole C-Curve MCB, 1 A, Dual-Rated Breaking Capacity

The Siemens SENTRON 5SY6601-7 is a 4-pole (3P+N) miniature circuit breaker with a C tripping characteristic, rated 1 A at AC per IEC/EN 60898-1 and IEC/EN 60947-2, with UL1077 recognition. At DC, it's rated 15 kA per IEC 60947-2, which covers battery-backed control circuits and UPS distribution. Temperature derating is published per the spec table: at 40 °C the rating drops to 0.95 A, at 50 °C to 0.9 A, and at 55 °C to 0.88 A. If the panel ambient hits 55 °C, the breaker will hold 0.88 A continuous without nuisance tripping — that's the number to use for load budgeting, not the 1 A label.

Standards & Compliance — What Each Rating Certifies

The 5SY6601-7 is certified to IEC/EN 60898-1 (the household/miniature breaker standard for overcurrent protection) and IEC/EN 60947-2 (the industrial breaker standard for isolation and higher fault levels), plus UL1077 for supplementary protection in North American panels. Touch protection is integrated on the terminals (IP20 with conductors connected), and the unit is sealable — the enclosure lid can be locked to prevent tampering. Halogen-free and silicon-free construction matter for high-reliability environments — no corrosive off-gassing during a fault, and no silicone outgassing to contaminate optics or contacts in sealed enclosures.

Panel Fit & Integration — DIN Rail, 4 MW, 76 mm Depth

Dimensions: 72 mm wide (4 MW), 90 mm tall, 76 mm deep. Installation depth is 70 mm — the extra 6 mm accounts for the terminal projection and arc-chamber clearance behind the DIN rail. Combined terminal top and bottom accept both busbar and conductor — no separate feed-through terminal needed.

Frequently asked questions

What is the breaking capacity of the 5SY6601-7?

6 kA per EN 60898-1, 30 kA per IEC 60947-2, and 15 kA at DC per IEC 60947-2. The 30 kA figure is the one to use for industrial panel SCCR coordination.

Where can I buy the 5SY6601-7 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock figure is published here.

What compliance documentation does the 5SY6601-7 carry?

IEC/EN 60898-1, IEC/EN 60947-2, and UL1077. Halogen-free and silicon-free construction. Pollution degree 3, overvoltage category III. RoHS/REACH declarations are standard with the brand's SENTRON series.

Will the 5SY6601-7 drop into a panel specified around the 5SY4140-7?

Both are 4-pole SENTRON MCBs on the same DIN-rail footprint. The 5SY6601-7 is a 1 A C-curve; the 5SY4140-7 is a 40 A C-curve. If the panel wiring and busbar are sized for 40 A, dropping in a 1 A breaker is electrically safe but will trip on the existing load — not a form-fit replacement without a load review.