Siemens 5SY6610-8 — 4-Pole MCB (DIN Rail)

Siemens 5SY6610-8 SENTRON MCB, D-curve 10A 4-pole 6kA

MPN5SY6610-8

Siemens SENTRON 5SY6 series, miniature circuit breaker, order code 5SY6610-8, 4-pole (3P+N), 10 A rated, D tripping characteristic, 6 kA breaking capacity per EN 60898, 15 kA per IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY6610-8 — Identification
ParameterValue
Type / order code5SY6
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY6610-8 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated current (In), AC400 V
Rated current (In), AC10 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
Rated voltage, DC (max.)72 V
Voltage typeAC
Rated frequency50/60 Hz
5SY6610-8 — Protection
ParameterValue
Tripping characteristic (trip curve)D
Rated breaking capacity (Icn), per EN 608986 kA
Rated breaking capacity, per IEC 60947-215 kA
Breaking capacity, AC (UL 1077 / CSA C22.2 No.235)5 kA
Overvoltage categoryIII
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingYes
Touch protectionYes
5SY6610-8 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
SealableYes
5SY6610-8 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY6610-8 — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

The Siemens 5SY6610-8 is a SENTRON miniature circuit breaker in the 5SY6 design series, rated 10 A at 400 V AC with a D tripping characteristic. Four poles configured as 3P+N, which covers three-phase plus neutral in a single module.

Breaking capacity is rated 6 kA per EN 60898 and 15 kA per IEC 60947-2 — the higher figure under the industrial standard gives you selectivity headroom downstream of a larger upstream device. At DC, the maximum rated voltage is 72 V with a 15 kA breaking capacity per IEC 60947-2. For UL 1077 and CSA C22.2 No. 235 applications, the interrupting rating is 5 kA at AC.

Mounts via the quick assembly system — snap onto DIN rail, any position. The housing is 72 mm wide (4 width units), 90 mm tall, 76 mm deep with a 70 mm installation depth. Combined terminals top and bottom accept solid or stranded conductors from 0.75 to 35 mm². IP20 with connected conductors; touch protection is built in. Halogen-free and silicon-free construction suits environments where outgassing matters, such as clean rooms or sealed enclosures.

Frequently asked questions

What is the breaking capacity of 5SY6610-8?

6 kA per EN 60898 and 15 kA per IEC 60947-2 at 400 V AC. At DC (72 V max) it is 15 kA per IEC 60947-2. For UL/CSA applications the rating is 5 kA.

Where can I buy 5SY6610-8?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What conductor sizes does the 5SY6610-8 terminal accept?

Solid and stranded conductors from 0.75 to 35 mm². Combined terminals at top and bottom.