Siemens 5SY6605-8 — 4-Pole MCB (DIN Rail)

Siemens 5SY6605-8 SENTRON MCB, 4P, D Curve, 0.5 A, 400 V

MPN5SY6605-8

Siemens SENTRON 5SY6 series, miniature circuit breaker, 4-pole (3P+N), D tripping characteristic, 0.5 A rated current at 400 V AC, 72 V DC max, 6 kA / 30 kA breaking capacity.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY6605-8 — Identification
ParameterValue
Type / order code5SY6
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY6605-8 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated current (In), AC400 V
Rated current (In), AC0.5 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
Rated voltage, DC (max.)72 V
Voltage typeAC
Rated frequency50/60 Hz
5SY6605-8 — Protection
ParameterValue
Tripping characteristic (trip curve)D
Rated breaking capacity (Icn), per EN 608986 kA
Rated breaking capacity, per IEC 60947-230 kA
Breaking capacity, AC (UL 1077 / CSA C22.2 No.235)5 kA
Overvoltage categoryIII
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingYes
Touch protectionYes
5SY6605-8 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
SealableYes
5SY6605-8 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY6605-8 — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

The Siemens 5SY6605-8 is a 4-pole (3P+N) SENTRON miniature circuit breaker with a D tripping characteristic, rated 0.5 A at 400 V AC. At 0.5 A, this is a low-current branch or control-circuit protector, not a main feeder breaker. The 4-pole construction with switched neutral suits three-phase circuits where you need all poles ganged, common in European industrial panels. Breaking capacity is rated 6 kA per EN 60898 and 30 kA per IEC 60947-2, with a DC rating of 15 kA at 72 V per IEC 60947-2 and 5 kA at AC per UL 1077 / CSA C22.2 No.235. The 30 kA IEC rating gives headroom for high-fault installations — a panel with upstream transformer capacity that could deliver substantial short-circuit current. The 6 kA EN 60898 rating is the standard household/commercial value; the 30 kA figure is what matters for industrial coordination studies.

Mounts via the quick assembly system — the standard DIN-rail clip for SENTRON 5SY6 breakers. Installation depth is 70 mm; total depth with the breaker body is 76 mm. Combined terminals top and bottom simplify busbar or ring-tongue connections.

Frequently asked questions

What are the key ratings for the 5SY6605-8?

Rated 0.5 A at 400 V AC, D tripping characteristic, 4-pole (3P+N). Breaking capacity: 6 kA per EN 60898, 30 kA per IEC 60947-2, 15 kA DC at 72 V per IEC 60947-2, and 5 kA per UL 1077 / CSA C22.2 No.235.

Where can I buy the 5SY6605-8?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for your quantity and delivery window.

What conductor sizes does the 5SY6605-8 accept?

Solid and stranded conductors from 0.75 to 35 mm². Combined terminals top and bottom accept the full range.

MPN
5SY6605-8