Skip to main content
Siemens 5SY6604-7 — 4-Pole MCB (DIN Rail)

Siemens 5SY6604-7 SENTRON MCB, 4A C-Curve 4P 30kA IEC

MPN5SY6604-7
Active

Siemens SENTRON 5SY6604-7, 4A C-curve miniature circuit breaker, 4-pole (3P+N), 30 kA breaking capacity per IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY6604-7 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY6604-7 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated current (In), AC4 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
5SY6604-7 — Protection
ParameterValue
Tripping characteristic (trip curve)C
Rated breaking capacity (Icn), per EN 608986 kA
Rated breaking capacity, per IEC 60947-230 kA
Breaking capacity, AC (UL 1077 / CSA C22.2 No.235)5 kA
Energy limitation class3
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
Touch protectionYes
5SY6604-7 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY6604-7 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY6604-7 — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

Lead — panel OEM wireman view

Integration — mounting and environment

Mounts in any position via the quick-assembly system (snap-on DIN rail). Operating temperature from -40 °C to 75 °C, with derating: at 40 °C the rated current drops to 3.81 A, at 55 °C to 3.5 A. Humidity derating applies above 55 °C.

Halogen-free and silicon-free construction. Sealable, with combined terminals top and bottom. Touch protection integrated. Energy limitation class 3. The product is designated under IEC 81346-2 and DIN EN 61346-2 as type F.

Frequently asked questions

Where can I buy 5SY6604-7?

The 5SY6604-7 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of 5SY6604-7?

It has a 30 kA breaking capacity per IEC 60947-2 and 6 kA per EN 60898.

What is the temperature derating for 5SY6604-7?

At 40 °C the rated current is 3.81 A; at 55 °C it drops to 3.5 A. The full operating range is -40 °C to 75 °C.

Will 5SY6604-7 fit in a panel designed for 5SY6006-7?

Yes — both are 4-pole MCBs in the SENTRON 5SY series with identical 72 mm width (4 MW) and 76 mm depth, so the 5SY6604-7 drops into the same DIN-rail footprint without rewiring.

What compliance documentation is available for 5SY6604-7?

The breaker is halogen-free, silicon-free, and carries touch protection. Compliance documents (RoHS, REACH, UL, IEC) are provided by Siemens for this SENTRON series.

MPN
5SY6604-7