Skip to main content
Siemens 5SY6604-7CC — 4-Pole MCB (DIN Rail)

Siemens 5SY6604-7CC SENTRON MCB, 4A C-Curve 4P 6kA

MPN5SY6604-7CC

Siemens SENTRON 5SY6604-7CC miniature circuit breaker, 4 A, C tripping characteristic, 4-pole (3P+N), 400 V AC, 6 kA per EN 60898, 5 kA per UL 1077.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY6604-7CC — Identification
ParameterValue
Type / order code5SY6CC
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY6604-7CC — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated current (In), AC400 V
Rated current (In), AC4 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
Rated voltage, DC (max.)72 V
Voltage typeAC
Rated frequency50/60 Hz
5SY6604-7CC — Protection
ParameterValue
Tripping characteristic (trip curve)C
Rated breaking capacity (Icn), per EN 608986 kA
Breaking capacity, AC (UL 1077 / CSA C22.2 No.235)5 kA
Overvoltage categoryIII
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingYes
Touch protectionYes
5SY6604-7CC — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
SealableYes
5SY6604-7CC — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY6604-7CC — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

Siemens 5SY6604-7CC SENTRON MCB — 4 A, C-Curve, 4-Pole

The Siemens 5SY6604-7CC is a SENTRON miniature circuit breaker rated 4 A at 400 V AC with a C tripping characteristic, configured 3P+N (4 poles). It breaks fault currents up to 6 kA per EN 60898 and 5 kA per UL 1077 / CSA C22.2 No. 235, covering both IEC and North American installations. The C-curve (5–10× In) is sized for moderate inrush loads — motor starters, contactor coils, small transformers — where the starting surge stays below 40 A before the thermal-magnetic trip clears a hard fault.

The 5SY6604-7CC occupies 4 width units (72 mm) on a DIN rail, with a depth of 76 mm and height of 90 mm. The quick-assembly mounting system snaps onto the rail without tools.

Frequently asked questions

Will the 5SY6604-7CC drop into a panel specified around the 5SY3132-6?

Both are 4-pole SENTRON MCBs on a 72 mm DIN-rail footprint, so the 5SY6604-7CC fits the same mechanical envelope. However, the 5SY3132-6 is a different current rating and tripping curve — verify the load's inrush and continuous current before swapping.

MPN
5SY6604-7CC