Skip to main content
Siemens 5SY6605-7 — Miniature Circuit Breakers (MCB)

Siemens 5SY6605-7 SENTRON MCB, 4P C 0.5 A, 6 kA

MPN5SY6605-7
Active

Siemens SENTRON 5SY6605-7, miniature circuit breaker, 4-pole (3P+N), C tripping characteristic, rated current 0.5 A, 400 V AC, breaking capacity 6 kA per EN 60898 / 30 kA per IEC 60947-2.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SY6605-7 — Ratings
ParameterValue
Overvoltage categoryIII
5SY6605-7 — Mechanical
ParameterValue
Width72 mm
Height90 mm
Depth76 mm

Product details

SENTRON 5SY6605-7 — 4-pole C-curve MCB at 0.5 A

The Siemens SENTRON 5SY6605-7 is a 4-pole miniature circuit breaker (3P+N) with a C tripping characteristic, rated at 0.5 A and 400 V AC. At 0.5 A, that magnetic threshold sits around 2.5 to 5 A, so it clears fast on a hard short but rides through the brief start-up surge of a small motor or solenoid.

Breaking capacity — which standard governs your panel

This breaker carries four breaking-capacity ratings, and the right one depends on the standard your panel is built to. Per EN 60898 it is rated 6 kA — the common domestic and light-commercial benchmark. For DC circuits, it is rated 15 kA at 72 V DC per IEC 60947-2. And for UL 1077 / CSA C22.2 No. 235 it is rated 5 kA at AC — the North American supplementary-protector standard. The 30 kA IEC figure gives real headroom in an industrial distribution board with a large upstream transformer.

Panel integration — DIN rail, 4 width units, any position

Touch protection is built in. The breaker is sealable — useful for installations where tamper-proofing the setting is required.

Environmental range and material compliance

Rated for ambient temperatures from -40 °C to +75 °C, with humidity derating: max 95% RH up to 55 °C, tapering to 35% RH at 75 °C. Overvoltage category III suits fixed-installation distribution boards.

Frequently asked questions

Who supplies 5SY6605-7 and how is it quoted for volume purchases?

This part is sourced through independent distribution channels. It is quoted to order against an RFQ — availability and current pricing are confirmed at quote time, including for volume or blanket-order requirements.

When sourcing 5SY6605-7, what is the closest functional second-source — 5SY6602-8?

The 5SY6602-8 is a peer in the same SENTRON 5SY6 family, but it is a 2-pole breaker with a different current rating and tripping characteristic. The 5SY6605-7 is 4-pole (3P+N), C-curve, 0.5 A. The 5SY6602-8 will not drop into a panel wired for 3P+N without rewiring the neutral and phase conductors.

What is 5SY6605-7's listed depth (76 mm) on this component line?

The depth is 76 mm, with an installation depth of 70 mm behind the panel surface.

What is 5SY6605-7's listed width (72 mm) on this component line?

The width is 72 mm, which corresponds to 4 width units (4 x 18 mm) on a standard DIN rail.

Will 5SY6605-7 drop into a panel that was specified around 5SY6602-8 without rewiring?

No. The 5SY6605-7 is a 4-pole (3P+N) breaker, while the 5SY6602-8 is 2-pole. The panel wiring and busbar arrangement would need to be changed to accommodate the additional poles and the neutral conductor switching function.

What compliance documentation does this brand provide for 5SY6605-7 (RoHS, REACH, UL, IEC)?

The breaker carries ratings per EN 60898 (6 kA), IEC 60947-2 (30 kA AC, 15 kA DC), and UL 1077 / CSA C22.2 No. 235 (5 kA). It is halogen-free and silicon-free, which supports RoHS/REACH compliance. The manufacturer provides a declaration of conformity and the relevant test certificates upon request through the RFQ process.

MPN
5SY6605-7