Skip to main content
Siemens 5SY6606-7CC — 4-Pole MCB (DIN Rail)

Siemens 5SY6606-7CC SENTRON MCB, 4P C-Curve 6A 6kA

MPN5SY6606-7CC

Siemens SENTRON 5SY6606-7CC, 4-pole (3P+N) miniature circuit breaker, C-curve, 6 A rated, 6 kA per EN 60898, 4 MW width, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY6606-7CC — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY6606-7CC — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated current (In), AC6 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
Voltage typeAC
5SY6606-7CC — Protection
ParameterValue
Tripping characteristic (trip curve)C
Rated breaking capacity (Icn), per EN 608986 kA
Breaking capacity, AC (UL 1077 / CSA C22.2 No.235)5 kA
Energy limitation class3
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingYes
Touch protectionYes
5SY6606-7CC — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY6606-7CC — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY6606-7CC — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

The 5SY6606-7CC is a 4-module-width (72 mm) SENTRON miniature circuit breaker with a C-curve trip characteristic, rated 6 A at 230/400 V AC and 50/60 Hz.

At 40 °C ambient the continuous current rating derates to 5.51 A; at 45 °C to 5.25 A; at 50 °C to 4.97 A; at 55 °C to 4.69 A. The breaker is rated for -40 °C to 75 °C ambient, with humidity limits of 95% up to 55 °C, 55% up to 70 °C, and 35% at 75 °C.

Breaking capacity and approvals

Rated breaking capacity is 6 kA per EN 60898 and 5 kA per UL 1077 / CSA C22.2 No. 235. Sealable for lockout/tagout.

Frequently asked questions

What is 5SY6606-7CC's depth?

76 mm overall depth, with a 70 mm installation depth into the enclosure.

What is 5SY6606-7CC's width?

72 mm, which corresponds to 4 modular width units on a DIN rail.

What compliance documentation is available for 5SY6606-7CC?

The breaker carries IEC 60898 (6 kA) and UL 1077 / CSA C22.2 No. 235 (5 kA) ratings. It is halogen-free and silicon-free. Standard SENTRON documentation includes RoHS and REACH declarations.

Where can I buy 5SY6606-7CC?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

Will 5SY6606-7CC drop into a panel specified around 5SY7210-7CC?

Both are 4-module SENTRON breakers with the same 72 mm width and 76 mm depth, so the mechanical fit and DIN-rail footprint are identical. The electrical difference is the rating and curve — the 5SY7210-7CC is a 10 A B-curve, while this is a 6 A C-curve. No rewiring is needed if the panel's busbar and load terminals match the 6 A C-curve rating.