Skip to main content
Siemens 5SY6608-8CC — 4-Pole MCB (DIN Rail)

Siemens 5SY6608-8CC SENTRON MCB, 4P D 8A, 6kA

MPN5SY6608-8CC

Siemens SENTRON 5SY6608-8CC, miniature circuit breaker, 4-pole (3P+N), D tripping characteristic, 8 A rated current AC, 6 kA breaking capacity acc. to EN 60898, 5 kA acc. to UL 1077.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY6608-8CC — Identification
ParameterValue
Type / order code5SY6CC
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY6608-8CC — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated current (In), AC400 V
Rated current (In), AC8 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
Rated voltage, DC (max.)72 V
Voltage typeAC
Rated frequency50/60 Hz
5SY6608-8CC — Protection
ParameterValue
Tripping characteristic (trip curve)D
Rated breaking capacity (Icn), per EN 608986 kA
Breaking capacity, AC (UL 1077 / CSA C22.2 No.235)5 kA
Overvoltage categoryIII
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingYes
Touch protectionYes
5SY6608-8CC — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
SealableYes
5SY6608-8CC — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY6608-8CC — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

The Siemens 5SY6608-8CC is a 4-module (72 mm wide) SENTRON miniature circuit breaker with a D tripping curve, rated 8 A at 400 V AC. The D characteristic means it tolerates inrush currents 10–20× rated — built for motor, transformer, or lighting ballast loads where the start-up spike would trip a B or C curve. Breaking capacity is 6 kA per EN 60898 and 5 kA per UL 1077 / CSA C22.2 No.235, which covers most industrial panel secondary faults. The 3P+N configuration switches the neutral pole, so it's suited for TN-S or TT systems where neutral isolation is required. Conductor terminations accept solid or stranded from 0.75 to 35 mm², with a screw-terminal torque range of 2.5–3.5 N·m. The top and bottom terminals are combined (line/load interchangeable), and the breaker carries touch protection (IP20 with conductors connected).

Depth is 76 mm (70 mm behind panel); the sealable cover option allows lockout-tagout compliance without removing the breaker. Four width units (72 mm) — verify DIN rail space before panel layout.

Frequently asked questions

Where can I buy 5SY6608-8CC and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

Does 5SY6608-8CC comply with UL and IEC standards?

Yes, it carries a 6 kA breaking capacity per EN 60898 and 5 kA per UL 1077 / CSA C22.2 No.235. The product is halogen-free and silicon-free, supporting RoHS/REACH compliance.

MPN
5SY6608-8CC