Skip to main content
Siemens 5SY6613-6 — 4-Pole MCB (DIN Rail)

Siemens SENTRON 5SY6613-6 MCB, 4-pole B-curve 13 A, 6/15 kA

MPN5SY6613-6
Active

Siemens SENTRON miniature circuit breaker, 5SY6613-6, 4-pole (3P+N), B-curve, 13 A, 6 kA per EN 60898 / 15 kA per IEC 60947-2, IP20, current production.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY6613-6 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY6613-6 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated current (In), AC13 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
Voltage typeAC
5SY6613-6 — Protection
ParameterValue
Tripping characteristic (trip curve)B
Rated breaking capacity (Icn), per EN 608986 kA
Rated breaking capacity, per IEC 60947-215 kA
Breaking capacity, AC (UL 1077 / CSA C22.2 No.235)5 kA
Energy limitation class3
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingYes
Touch protectionYes
5SY6613-6 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY6613-6 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C

Product details

The Siemens SENTRON 5SY6613-6 is a 4-pole miniature circuit breaker (3P+N) with a B-curve trip characteristic, rated 13 A at 50/60 Hz AC. It is designed for branch-circuit overcurrent and short-circuit protection in industrial control panels, distribution boards, and mechanical-engineering installations.

The 13 A rating holds at 35 °C; derate to 12.48 A at 40 °C, 12.22 A at 45 °C, 11.95 A at 50 °C, and 11.67 A at 55 °C — plan your continuous load against the ambient temperature of the enclosure. The higher IEC figure applies when the breaker is used in industrial distribution with a known upstream fault level; the EN figure governs in residential or light-commercial boards. Mounts in any position via the quick-assembly system — snaps onto standard DIN rail.

Halogen-free and silicon-free construction reduces corrosive off-gassing in enclosed panels. Sealable for lockout/tagout. Ambient temperature range -40 to 75 °C with humidity limits per.

Frequently asked questions

Where can I buy 5SY6613-6 and how do I get a price?

The 5SY6613-6 is sourced to order through independent distribution. Submit an RFQ for current pricing and availability — confirmed at quote time.

Will 5SY6613-6 drop into a panel that was specified around 5SY6613-8 without rewiring?

Both are 4-pole (3P+N) SENTRON MCBs with the same DIN-rail footprint (72 mm width, 4 modular units) and identical depth (76 mm). The 5SY6613-6 is a 13 A B-curve; the 5SY6613-8 is a different rating. Physical swap is possible if the ampacity and trip curve match the circuit design — verify the load before substituting.

What compliance documentation does this brand provide for 5SY6613-6 (RoHS, REACH, UL, IEC)?

The 5SY6613-6 is certified to EN 60898 (6 kA) and IEC 60947-2 (15 kA). It carries the Siemens SENTRON brand and is halogen-free and silicon-free. For RoHS/REACH declarations and UL listing status, request the manufacturer's compliance documentation at quote time.

MPN
5SY6613-6