Skip to main content
Siemens 5SY6616-7CC — 4-Pole MCB (DIN Rail)

Siemens 5SY6616-7CC SENTRON MCB, 16 A, 4-pole, C-curve, 6 kA

MPN5SY6616-7CC

Siemens SENTRON 5SY6616-7CC miniature circuit breaker, 4-pole (3P+N), 16 A, C-curve, 6 kA breaking capacity per EN 60898, 5 kA per UL 1077, 400 V AC, IP20, quick-assembly mounting.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY6616-7CC — Identification
ParameterValue
Type / order code5SY6CC
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY6616-7CC — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated current (In), AC400 V
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
Rated voltage, DC (max.)72 V
Voltage typeAC
Rated frequency50/60 Hz
5SY6616-7CC — Protection
ParameterValue
Tripping characteristic (trip curve)C
Rated breaking capacity (Icn), per EN 608986 kA
Breaking capacity, AC (UL 1077 / CSA C22.2 No.235)5 kA
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingYes
Touch protectionYes
5SY6616-7CC — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY6616-7CC — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY6616-7CC — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

Integrator note — 5SY6616-7CC

The Siemens 5SY6616-7CC is a SENTRON miniature circuit breaker (MCB) rated 16 A at 400 V AC, 4-pole (3P+N), with a C tripping characteristic. It breaks 6 kA per EN 60898 and 5 kA per UL 1077 / CSA C22.2 No.235 — enough for most industrial panel branch circuits. Mounts via the quick-assembly system (DIN rail compatible) and occupies 4 width units (72 mm). The neutral pole is switched (3P+N), so it fits 3-phase + N panels where you need to isolate the neutral on fault.

Electrical environment

The 50/60 Hz rating covers both 50 Hz European and 60 Hz North American line frequencies. Ambient temperature range -40 to 75 °C, with derating above 55 °C per the humidity/temperature influence curve (max 95% RH to 55 °C, 55% RH to 70 °C, 35% RH to 75 °C). Energy limiting class 3 means it limits let-through energy well — important for downstream cable and device protection in a coordinated panel. Sealable terminals (top and bottom combined) allow tamper-proofing for metering or safety circuits.

Compliance & approvals

Designed per EN 60898 (6 kA) and UL 1077 / CSA C22.2 No.235 (5 kA), so it carries dual IEC and North American supplementary protection ratings. The 5SY6CC design variant is listed for mechanical engineering and industrial applications.

Frequently asked questions

What is the breaking capacity of 5SY6616-7CC?

6 kA per EN 60898 and 5 kA per UL 1077 / CSA C22.2 No.235 at 400 V AC.

What is the difference between 5SY6616-7CC and 5SY3132-6?

The 5SY3132-6 is a 2-pole 32 A B-curve MCB in the same SENTRON 5SY family; the 5SY6616-7CC is a 4-pole 16 A C-curve. They share the same DIN-rail footprint and terminal design, but pole count, current rating, and trip curve differ — they are not direct drop-in replacements without rewiring and coordination review.

Where can I buy 5SY6616-7CC?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
5SY6616-7CC