Siemens 5SY6640-7CC — 4-Pole MCB (DIN Rail)

Siemens 5SY6640-7CC SENTRON MCB, 40A 4P C-Curve, 6kA IEC

MPN5SY6640-7CC

Siemens SENTRON 5SY6640-7CC, 4-pole miniature circuit breaker, 40 A rated, C tripping characteristic, 6 kA breaking capacity (EN 60898), 5 kA (UL 1077), IP20, current production.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY6640-7CC — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY6640-7CC — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated current (In), AC40 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
5SY6640-7CC — Protection
ParameterValue
Tripping characteristic (trip curve)C
Rated breaking capacity (Icn), per EN 608986 kA
Breaking capacity, AC (UL 1077 / CSA C22.2 No.235)5 kA
Energy limitation class3
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
Touch protectionYes
5SY6640-7CC — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY6640-7CC — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY6640-7CC — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

The 4-pole (3P+N) design covers three-phase circuits with a switched neutral, common in European distribution boards.

Derating and ambient temperature — the real-world current limit

The 40 A rating holds at 35 °C. At 40 °C it derates to 38.12 A, at 45 °C to 37.12 A, at 50 °C to 36.12 A, and at 55 °C to 35.08 A. If the panel runs warm — say 50 °C inside the enclosure — the breaker's effective continuous current is 36 A, not 40. The surrounding temperature influence curve also caps humidity: 95 % RH up to 55 °C, then 55 % RH up to 70 °C, then 35 % RH up to 75 °C.

Panel fit — DIN-rail footprint and mounting

Width is 72 mm (4 modular units), depth 76 mm, height 90 mm. Fastening method is snap-on, any mounting position.

Comparison with 5SY7210-7CC — same footprint, different rating

The 5SY7210-7CC is a physically identical 4-pole SENTRON MCB but rated at a lower current (10 A vs 40 A) with the same C curve and breaking capacity. The choice is purely the load current: 40 A for feeder circuits or larger loads, 10 A for branch protection. No footprint or coordination change needed.

Frequently asked questions

What is the breaking capacity of 5SY6640-7CC?

6 kA per EN 60898 and 5 kA per UL 1077. The UL figure is the one to check for North American panel listings.

Will 5SY6640-7CC fit in a panel designed for 5SY7210-7CC?

Yes — same 72 mm width, same 4-pole footprint, same DIN-rail mounting. The only difference is the current rating: 40 A vs 10 A. No rewiring or enclosure modification needed.

How do I get current pricing and availability for 5SY6640-7CC?

Submit an RFQ through the storefront. The part is sourced to order via independent distribution; availability and current pricing are confirmed at quote time.