Siemens SENTRON 5SY6650-8CC MCB, 4P 50A D-curve, 6kA

MPN5SY6650-8CC

Siemens SENTRON miniature circuit breaker, 4-pole (3P+N), 50 A, D tripping characteristic, 6 kA breaking capacity per EN 60898, 400 V AC, 4 MW units wide.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY6650-8CC — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY6650-8CC — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated voltage, AC (multi-phase)440 V
5SY6650-8CC — Protection
ParameterValue
Tripping characteristic (trip curve)D
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
5SY6650-8CC — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY6650-8CC — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY6650-8CC — Performance
ParameterValue
Power loss per pole, AC (hot state, at In)3.8 W

Product details

The Siemens SENTRON 5SY6650-8CC is a 4-pole miniature circuit breaker (3P+N) with a D tripping characteristic, rated 50 A at 400 V AC. At 4 modular width units (72 mm wide, 76 mm deep, 90 mm tall), it occupies standard DIN-rail space — the same footprint as any 4-pole SENTRON 5SY series breaker. The neutral pole is switched (3P+N), so it disconnects the neutral conductor, which matters for TN-S or TT systems where you need full isolation on all live conductors.

Ambient temperature range -40 °C to +75 °C, with humidity derating above 55 °C (95% RH at 55 °C, tapering to 35% at 75 °C). Vibration resistance per IEC 60068-2-6: ±1 mm at 5–25 Hz, 50 m/s² at 25–150 Hz. Supplementary devices (aux contacts, shunt trips, alarm switches) can be installed on either side via the combined top/bottom terminals.

D-curve and load suitability

The D characteristic (tripping between 10× and 20× In) is the right choice for loads with high inrush: small motors, pumps, compressors, transformers, and discharge lighting. A C-curve breaker of the same rating would nuisance-trip on the same start-up surge.

Frequently asked questions

Where can I buy 5SY6650-8CC?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment.

What is the breaking capacity of 5SY6650-8CC?

6 kA per EN 60898 at 400 V AC (cite:), and 5 kA per UL 1077 and CSA C22.2 No. 235 (cite:).

What is the width of 5SY6650-8CC in modular units?

4 modular width units, which is 72 mm wide (cite:,). Depth is 76 mm, height 90 mm.

Will 5SY6650-8CC drop into a panel specified around a different 4-pole SENTRON MCB?

Yes — the 72 mm width (4 MW) and DIN-rail mounting are standard across the SENTRON 5SY 4-pole family. The footprint is identical; no rewiring of the busbar or DIN rail is needed if the replacement is also a 4-pole SENTRON breaker of the same pole count.

What compliance documentation does Siemens provide for 5SY6650-8CC?

The part carries EN 60898 rating (cite:) and UL 1077 / CSA C22.2 No. 235 listing (cite:). It is halogen-free and silicon-free (cite:,). Standard Siemens declarations (CE, UKCA, RoHS, REACH) apply to the SENTRON series; request the specific declaration of conformity with your RFQ.