Siemens 5SY7105-7 — 1-Pole MCB (DIN Rail)

Siemens 5SY7105-7 SENTRON MCB, 1P, 0.5 A, C-Curve, 15/50 kA

MPN5SY7105-7
Active

Siemens SENTRON 5SY7105-7, 1-pole miniature circuit breaker, 0.5 A rated current, C tripping characteristic, 15 kA (EN 60898) / 50 kA (IEC 60947-2) breaking capacity, 18 mm wide, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SY7105-7 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityMechanical engineering / industry
5SY7105-7 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Energy limitation class3
Overvoltage categoryIII
5SY7105-7 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY7105-7 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

Siemens 5SY7105-7 — 0.5 A C-Curve MCB for Control and Lighting Circuits

It carries a 15 kA breaking capacity per EN 60898-1 and a 50 kA rating per IEC 60947-2 / UL1077, meaning it can safely interrupt fault currents up to those levels without upstream cascading — critical for selectivity coordination in a distribution board.

The 0.5 A rated current at 35 °C derates to 0.47 A at 40 °C and 0.4 A at 60 °C (–). If your enclosure runs warm — say, next to a transformer or drive — size the load below the derated figure, not the 35 °C number. The C-curve trips magnetically at 5–10× In, so it's suited for moderate inrush loads like contactor coils or small transformers, not pure resistive heaters (use B-curve) or heavy motor starts (use D-curve). The dual breaking capacity — 15 kA per EN 60898 and 50 kA per IEC 60947-2 — reflects the same hardware tested to two standards. The 50 kA figure applies when the breaker is used as a distribution circuit breaker per 60947-2; the 15 kA figure applies when used as a domestic/industrial MCB per 60898. For industrial panels, treat the 50 kA as your SCCR headroom, but verify the upstream fuse or breaker limits the prospective fault current to that value.

Mounting position is any; installation depth is 70 mm. Sealable allows lockout/tagout compliance.

Frequently asked questions

What is the breaking capacity of the 5SY7105-7?

15 kA per EN 60898-1 and 50 kA per IEC 60947-2 / UL1077. The higher figure applies when the breaker is used as a distribution circuit breaker per 60947-2.

What compliance documentation does Siemens provide for the 5SY7105-7?

The breaker is certified to IEC/EN 60898-1, IEC/EN 60947-2, and UL1077. It is halogen-free and silicon-free. RoHS and REACH declarations are standard from Siemens for this series.

Where can I buy the 5SY7105-7 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or price is published here.

MPN
5SY7105-7