Siemens 5SY7105-8CC SENTRON MCB, 1P D 0.5A, 50kA IEC

MPN5SY7105-8CC

Siemens SENTRON 5SY7105-8CC, 1-pole D-curve miniature circuit breaker, 0.5 A rated, 230/400 V AC, 50 kA breaking capacity per IEC 60947-2, 18 mm width.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SY7105-8CC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityMechanical engineering / industry
5SY7105-8CC — Electrical & Protection
ParameterValue
Tripping characteristic classD
Overvoltage categoryIII
5SY7105-8CC — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY7105-8CC — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens SENTRON 5SY7105-8CC is a 1-pole miniature circuit breaker with a D tripping characteristic, rated at 0.5 A for 230/400 V AC circuits. It's built for high-inrush loads — motor starters, transformers, or switching power supplies — where the D-curve's magnetic trip at 10–20x rated current avoids nuisance tripping on startup.

Fit and footprint

Mounting position any, so it works in vertical or horizontal busbar layouts. IP20 with connected conductors, meaning it's enclosed in a panel, not exposed on the line side.

Approvals and environment

The 5 kA breaking capacity per UL 1077 / CSA C22.2 No.235 covers North American supplementary protection applications. Halogen-free and silicon-free construction, so it won't outgas corrosive compounds in sealed panels near sensitive electronics.

Frequently asked questions

Where can I buy 5SY7105-8CC and what is the lead time?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm lead time.

What is the breaking capacity of 5SY7105-8CC?

50 kA per IEC 60947-2 at 400 V AC, and 5 kA per UL 1077 / CSA C22.2 No.235 for North American supplementary protection.

Will 5SY7105-8CC drop into a panel specified around 5SY4101-7CV without rewiring?

Both are 1-pole SENTRON MCBs on the same 18 mm DIN-rail footprint, so the mechanical fit is identical. The difference is the tripping curve — 5SY7105-8CC is a D-curve (10–20x In) for high-inrush loads, while 5SY4101-7CV is a B-curve (3–5x In) for resistive or general-purpose circuits. If the panel was designed for a B-curve, swapping to a D-curve may reduce nuisance tripping on motor starts but could also reduce fault selectivity with downstream B-curve breakers. Check the coordination study before swapping.

What compliance documentation is available for 5SY7105-8CC?

The part carries IEC 60947-2 and UL 1077 / CSA C22.2 No.235 approvals. It is halogen-free and silicon-free, which supports RoHS and REACH compliance declarations. Specific certificates are available on request with an RFQ.