Siemens 5SY7110-7CC — 1-Pole MCB (DIN Rail)

Siemens 5SY7110-7CC SENTRON MCB, 1P C-Curve, 15 kA IEC 60898

MPN5SY7110-7CC

Siemens SENTRON 5SY7110-7CC miniature circuit breaker, 1-pole, C-curve, 15 kA (IEC 60898) / 25 kA (IEC 60947-2), 18 mm width, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY7110-7CC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityMechanical engineering / industry
5SY7110-7CC — Electrical & Protection
ParameterValue
Tripping characteristic classC
Overvoltage categoryIII
5SY7110-7CC — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY7110-7CC — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

What this 1-pole C-curve MCB delivers in a panel

The Siemens 5SY7110-7CC is a 1-pole SENTRON miniature circuit breaker with C-curve tripping characteristic, rated 15 kA breaking capacity per EN 60898 and 25 kA per IEC 60947-2. At 18 mm wide (1 modular unit), it fits a standard DIN-rail enclosure with no special adapter.

Where it fits — and where it doesn't

Rated for AC supply only, 50/60 Hz, with a maximum operating voltage of 440 V single-phase or multi-phase. The DC rating tops out at 72 V — don't spec this for a 125 V DC control bus. For North American panels, note the UL 1077 / CSA C22.2 No.235 rating is 5 kA — a third of the IEC 60947-2 figure. If your job requires a 10 kA or 14 kA SCCR under UL, this breaker alone won't carry it; you'd need to verify the combination with the upstream fuse or breaker in the assembly listing. Ambient temperature range is -40 °C to 75 °C, with derating above 55 °C per the humidity table (max 95% RH at 55 °C, dropping to 35% at 75 °C). Vibration resistance per IEC 60068-2-6: ±1 mm at 5–25 Hz, 50 m/s² at 25–150 Hz — fine for most industrial machinery but not locomotive or off-road mobile equipment without additional qualification.

Frequently asked questions

Where can I buy 5SY7110-7CC and get a price?

This part is sourced to order against an RFQ through independent distribution. Submit a request for quote — availability and current pricing are confirmed at quote time.

Will 5SY7110-7CC drop into a panel specified around 5SY4101-7CV without rewiring?

Both are 1-pole SENTRON MCBs in an 18 mm modular footprint, so the mechanical fit on the DIN rail and busbar system is identical. The 5SY7110-7CC carries a C-curve and 15 kA IEC breaking capacity, while the 5SY4101-7CV is a different variant — verify the tripping curve and interrupting rating against your panel's short-circuit study before swapping. No rewiring needed for the same pole count and busbar pitch.

What compliance documentation does Siemens provide for 5SY7110-7CC?

The part is halogen-free and silicon-free, which supports RoHS and REACH compliance declarations. It carries ratings per IEC 60898, IEC 60947-2, and UL 1077 / CSA C22.2 No.235 — the manufacturer typically provides a declaration of conformity covering these standards.

MPN
5SY7110-7CC