Siemens 5SY7120-8CC — 1-Pole MCB (DIN Rail)

Siemens 5SY7120-8CC SENTRON MCB, 1P D 20A 25kA

MPN5SY7120-8CC

Siemens SENTRON 5SY7120-8CC, 1-pole miniature circuit breaker, D tripping characteristic, 20 A rated current at AC, 25 kA breaking capacity per IEC 60947-2, 18 mm width.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY7120-8CC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityMechanical engineering / industry
5SY7120-8CC — Electrical & Protection
ParameterValue
Tripping characteristic classD
Overvoltage categoryIII
5SY7120-8CC — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY7120-8CC — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens 5SY7120-8CC is a 1-pole SENTRON miniature circuit breaker with a D tripping characteristic, rated 20 A at AC and a breaking capacity of 25 kA per IEC 60947-2. The D-curve means it tolerates inrush currents typical of motor and transformer loads without nuisance tripping; the 20 A rating is the continuous thermal current at 35 °C, derating to 17.78 A at 40 °C and 15.26 A at 50 °C.

The 18 mm width and 76 mm depth mean it occupies one module slot; installation depth is 70 mm.

Thermal derating and environmental limits

The 20 A rating holds at 35 °C. Above that, the continuous current must be reduced: 17.78 A at 40 °C, 16.56 A at 45 °C, 15.26 A at 50 °C, 13.82 A at 55 °C (–). Humidity limits apply: max 95% RH up to 55 °C, then 55% RH up to 70 °C, then 35% RH up to 75 °C.

Selectivity and coordination

The D-curve provides magnetic trip at 10–20× In, so it coordinates with upstream SENTRON selective main breakers. Rated frequency is 50/60 Hz. Sealable for lockout/tagout compliance.

Frequently asked questions

What is the breaking capacity of 5SY7120-8CC?

25 kA at 440 V AC per IEC 60947-2. This is the maximum fault current it can safely interrupt under standard test conditions.

Where can I buy 5SY7120-8CC?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Will 5SY7120-8CC fit in a panel designed for 5SY7210-7CC?

Both are 1-pole SENTRON MCBs in an 18 mm modular width, so the physical footprint is identical. The difference is the tripping characteristic: D-curve on the 5SY7120-8CC versus a different curve on the 5SY7210-7CC. Check the peer's characteristic before swapping.