Skip to main content
Siemens 5SY7201-8CC — 2-Pole MCB (DIN Rail)

Siemens 5SY7201-8CC SENTRON MCB, 1A D-curve 2P, 50kA IEC

MPN5SY7201-8CC

Siemens SENTRON 5SY7201-8CC, miniature circuit breaker, 2-pole, 1 A rated, D tripping characteristic, 400 V AC, 50 kA IEC 60947-2, 5 kA UL 1077, 2 width units, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY7201-8CC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentMechanical engineering / industry
5SY7201-8CC — Electrical
ParameterValue
Number of poles2
5SY7201-8CC — Protection
ParameterValue
Tripping characteristic classD
Overvoltage categoryIII
5SY7201-8CC — Mechanical
ParameterValue
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Protection degree (IP)IP20, with connected conductors

Product details

Siemens 5SY7201-8CC SENTRON MCB — 1A D-curve, 2-pole

The Siemens 5SY7201-8CC is a 2-pole miniature circuit breaker from the SENTRON 5SY7 series, rated 1 A at 400 V AC with a D tripping characteristic — meaning it handles high inrush currents typical of motor, transformer, or lighting ballast loads without nuisance tripping, while still clearing a fault at 50 kA per IEC 60947-2 or 5 kA per UL 1077.

The 1 A rated current and D-curve (10–20x In magnetic trip) make this the right choice for a circuit feeding a small motor starter, a control transformer, or a bank of LED drivers where the startup surge exceeds what a B- or C-curve would tolerate without tripping. The 5 kA rating under UL 1077 and CSA C22.2 No. 235 covers North American installations where the available fault current is lower. Wire range accepts 0.75 to 35 mm² solid or stranded, and the screw terminals call for 2.5 to 3.5 N·m torque — that's a wide lugging range for a 1 A breaker, letting you land a fat feeder or a thin control wire without adapters.

Combined terminals top and bottom mean you can feed from either end, and the sealable cover lets you lock settings after commissioning.

Lifecycle stage is current — no phase-out or last-time-buy notice on this order code. If you're holding a BOM that specifies the 5SY7140-8CC (a 40 A D-curve 2P), this 1 A version shares the same 2-pole, D-curve, 5SY7CC design and the same physical footprint — 36 mm wide, 76 mm deep, same terminals — so it's a drop-in swap for the same frame size at a different current rating.

The 5SY7201-8CC carries IEC 60947-2 and UL 1077 / CSA C22.2 No. 235 approvals — covering the main international and North American standards for supplementary protectors. Overvoltage category III means it's rated for fixed-installation distribution panels, not just downstream equipment. Siemens provides the standard declaration of conformity and CE marking for this SENTRON series; RoHS and REACH compliance documentation is available on request through the supply channel.

Frequently asked questions

What is the breaking capacity of the 5SY7201-8CC?

It's rated 50 kA at 400 V AC per IEC 60947-2 and 5 kA per UL 1077 and CSA C22.2 No. 235. The 50 kA figure is the high-fault rating for industrial panels; the 5 kA UL rating covers North American supplementary protector applications.

Will the 5SY7201-8CC drop into a panel specified for the 5SY7140-8CC?

Yes — both are 2-pole D-curve breakers in the same 5SY7CC design, same 36 mm width, same 76 mm depth, same terminal layout. The only difference is the current rating: 1 A vs 40 A. No rewiring or panel modification needed.

Where can I buy the 5SY7201-8CC and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — send an RFQ for your volume and we'll respond with a firm offer.

MPN
5SY7201-8CC