Skip to main content
Siemens 5SY7203-8 — 2-Pole MCB (DIN Rail)

Siemens 5SY7203-8 SENTRON MCB, 2P D-curve, 15kA IEC 60898-1

MPN5SY7203-8
Active

Siemens SENTRON 5SY7203-8, 2-pole miniature circuit breaker, D tripping characteristic, 15 kA (IEC 60898-1) / 40 kA (IEC 60947-2), 400 V AC, 60 V DC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY7203-8 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentMechanical engineering / industry
5SY7203-8 — Electrical
ParameterValue
Number of poles2
5SY7203-8 — Protection
ParameterValue
Tripping characteristic classD
Overvoltage categoryIII
5SY7203-8 — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SY7203-8 — Environmental
ParameterValue
Pollution degree3
5SY7203-8 — Specifications
ParameterValue
At AC rated value400 V
According to EN 60898 rated value15 kA
With single-phase operation at AC rated value440 V

Product details

What this MCB is and what the ratings mean

The Siemens 5SY7203-8 is a 2-pole miniature circuit breaker from the SENTRON family, designed for branch-circuit protection in industrial control panels. The D tripping characteristic means it tolerates high inrush currents — typically found with motor loads, transformers, or welding equipment — without nuisance tripping on startup. The 15 kA breaking capacity per IEC 60898-1 is the rating for domestic-type installations; the 40 kA per IEC 60947-2 is the industrial rating, telling you this breaker can safely interrupt a fault current up to 40 kA at 400 V AC in an industrial distribution board. That 40 kA figure is the one that matters for panel SCCR calculations in a plant environment.

Panel fit and mounting

Width is 36 mm (2 modular units), depth 76 mm, height 90 mm. Snaps onto DIN rail via the quick-assembly system; mounting position is any, which helps when you're packing a dense gland plate. The IP20 rating applies with conductors connected — standard for inside a closed panel. Installation depth is 70 mm, so plan for that behind the DIN rail.

Standards and compliance

Rated to IEC / EN 60898-1 and IEC / EN 60947-2, plus UL 1077. That dual rating covers both residential-style and industrial applications. The breaker is halogen-free and silicon-free, which matters for clean-room or sensitive electronics environments. Pollution degree 3 and overvoltage category III suit it for fixed industrial installations.

Frequently asked questions

What is the breaking capacity of 5SY7203-8?

15 kA per IEC 60898-1 and 40 kA per IEC 60947-2 at 400 V AC. At DC (60 V) it is 15 kA per IEC 60947-2. Under UL 1077 it is 5 kA.

Will 5SY7203-8 drop into a panel specified for 5SY4140-7?

Both are 2-pole SENTRON MCBs on the same DIN-rail footprint, so the mechanical fit is the same. The difference is tripping characteristic: 5SY7203-8 is D-curve (for motor/transformer loads), while 5SY4140-7 is B-curve (for resistive/light loads). Verify the load type before swapping.

Where can I buy 5SY7203-8 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
5SY7203-8