Specifications

5SY7206-6 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentMechanical engineering / industry
5SY7206-6 — Electrical
ParameterValue
Number of poles2
5SY7206-6 — Protection
ParameterValue
Tripping characteristic classB
Overvoltage categoryIII
5SY7206-6 — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SY7206-6 — Environmental
ParameterValue
Pollution degree3
5SY7206-6 — Specifications
ParameterValue
At AC rated value400 V
According to EN 60898 rated value15 kA
With single-phase operation at AC rated value440 V
Energy Limitation Class3

Product details

Siemens 5SY7206-6 SENTRON Miniature Circuit Breaker – 2-Pole, B-Curve

The Siemens 5SY7206-6 is a 2-pole miniature circuit breaker from the SENTRON family, with a B tripping characteristic and a rated breaking capacity of 15 kA per IEC/EN 60898-1 and 40 kA per IEC 60947-2. It is rated for 440 V AC (single- or multi-phase) and 72 V DC maximum, at 50/60 Hz. The B-curve trips between 3 and 5 times rated current, making it a standard choice for general-purpose branch-circuit protection in commercial and industrial panels — not for motor-starting inrush, but fine for lighting, receptacle, and control-transformer circuits.

Breaking Capacity & Standards Compliance

This breaker carries a 15 kA rating per IEC/EN 60898-1 (the domestic and light-commercial MCB standard) and a 40 kA rating per IEC 60947-2 (the industrial circuit-breaker standard). The 40 kA figure means it can safely interrupt high fault currents in industrial panels without upstream fuses — useful when the available fault current at the panel is above 15 kA. For UL 1077 and CSA C22.2 No. 235 applications, the rating is 5 kA. The part also meets pollution degree 3 and overvoltage category III, so it is suitable for fixed installations in enclosures where conductive contamination is possible. The 5SY7206-6 is halogen-free and silicon-free, which matters for panels in clean-room, semiconductor, or food-processing environments where outgassing or silicone contamination must be avoided.

Panel Integration & Mounting

The breaker snaps onto a DIN rail (35 mm) using the quick-assembly system and occupies 2 modular width units (36 mm). Mounting position is any, so it can be installed horizontally or vertically without derating. The IP20 rating applies with connected conductors — standard for enclosed panel use. Combined terminals at top and bottom accept the same wire range, simplifying wiring. Depth is 76 mm (installation depth 70 mm), leaving clearance behind the DIN rail.

Environmental Range & Derating

The 5SY7206-6 operates from -40 °C to 75 °C, with humidity derating: max 95% RH at 55 °C, tapering to 35% RH at 75 °C. That covers most indoor industrial panels and even unheated outdoor enclosures in temperate climates. The sealable feature allows the installer to lock the toggle position with a padlock for lockout/tagout compliance.

Frequently asked questions

How do I get current pricing and availability for the 5SY7206-6?

Submit an RFQ with your target quantity. The part is quoted to order against your request — availability and pricing are confirmed at quote time through our independent distribution network.

What compliance documentation does the 5SY7206-6 carry?

It is certified to IEC/EN 60898-1, IEC/EN 60947-2, and UL 1077 / CSA C22.2 No. 235. It is also halogen-free and silicon-free, which supports RoHS/REACH compliance statements from Siemens.

What is the breaking capacity of the 5SY7206-6?

15 kA per IEC/EN 60898-1, 40 kA per IEC 60947-2, and 5 kA per UL 1077 / CSA C22.2 No. 235. The DC breaking capacity is 15 kA per IEC 60947-2.

Will the 5SY7206-6 drop into a panel specified for the 5SY4116-6CC?

Both are 2-pole SENTRON MCBs on the same DIN-rail footprint (2 MW, 36 mm wide). The 5SY7206-6 uses a B-curve; the 5SY4116-6CC uses a C-curve. If the panel's branch circuits expect a C-curve (higher inrush tolerance, e.g. for small motors), swapping to a B-curve may cause nuisance tripping on startup. Otherwise the mechanical fit is identical.

MPN
5SY7206-6