Skip to main content
Siemens 5SY7210-8CC — 2-Pole MCB (DIN Rail)

Siemens 5SY7210-8CC SENTRON MCB, 10 A D-Curve, 25 kA

MPN5SY7210-8CC

Siemens SENTRON 5SY7210-8CC, 2-pole miniature circuit breaker, D characteristic, 10 A rated current, 25 kA IEC 60947-2 breaking capacity at 400 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY7210-8CC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentMechanical engineering / industry
5SY7210-8CC — Electrical
ParameterValue
Number of poles2
5SY7210-8CC — Protection
ParameterValue
Tripping characteristic classD
Overvoltage categoryIII
5SY7210-8CC — Mechanical
ParameterValue
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SY7210-8CC — Environmental
ParameterValue
Pollution degree3

Product details

Breaking capacity hits 25 kA per IEC 60947-2 and 5 kA per UL 1077/CSA C22.2 No. 235, so it handles substantial fault current in industrial panels. Mounts on a 36 mm wide DIN rail (2 width units) via the quick-assembly system; any mounting position is acceptable. The 76 mm depth leaves room in shallow enclosures, and the 70 mm installation depth matches standard SENTRON comb-busbar grids. Touch protection is integrated, and the sealable design allows lockout-tagout compliance on the panel door.

The halogen-free and silicon-free construction supports clean-room and sensitive electronics environments.

Peer comparison: 5SY7140-8CC

The closest functional peer is the 5SY7140-8CC, which shares the same D-curve, 2-pole form factor, and SENTRON 5SY7CC design. The difference is rated current: 10 A on the 5SY7210-8CC versus 14 A on the 5SY7140-8CC. Both carry 25 kA IEC breaking capacity. If a panel was specified around the 5SY7140-8CC, swapping to the 5SY7210-8CC requires verifying the load current does not exceed 10 A — the footprint and busbar pitch are identical, so no rewiring is needed beyond the ampacity check.

Frequently asked questions

Who supplies 5SY7210-8CC and how is it quoted for volume purchases?

Sourced through independent distribution channels. Volume pricing and lead time are confirmed at the time of an RFQ — submit a request for a current quote.

What is 5SY7210-8CC's listed depth?

The depth is 76 mm, with an installation depth of 70 mm. The overall dimensions are 76 mm deep × 36 mm wide × 90 mm high.

Will 5SY7210-8CC drop into a panel specified around 5SY7140-8CC without rewiring?

Yes — both are 2-pole, 36 mm wide units from the same SENTRON 5SY7CC family. The only difference is the 10 A rating versus 14 A. No rewiring is needed as long as the branch load does not exceed 10 A.

What compliance documentation does Siemens provide for 5SY7210-8CC?

The part carries UL 1077 and CSA C22.2 No. 235 approvals, and is RoHS, REACH, halogen-free, and silicon-free compliant. Declarations are available from the manufacturer.

MPN
5SY7210-8CC