Skip to main content
Siemens 5SY7240-8 — 2-Pole MCB (DIN Rail)

Siemens 5SY7240-8 SENTRON MCB, 2P, 40 A, D Curve, 15 kA

MPN5SY7240-8
Active

Siemens SENTRON 5SY7240-8 miniature circuit breaker, 2-pole, 40 A, D tripping characteristic, 15 kA (EN 60898) / 20 kA (IEC 60947-2), 2 MW.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SY7240-8 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentMechanical engineering / industry
5SY7240-8 — Electrical
ParameterValue
Number of poles2
5SY7240-8 — Protection
ParameterValue
Tripping characteristic classD
Overvoltage categoryIII
5SY7240-8 — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SY7240-8 — Environmental
ParameterValue
Pollution degree3

Product details

The Siemens 5SY7240-8 is a 2-pole SENTRON miniature circuit breaker rated 40 A with a D tripping characteristic, designed to protect branch circuits against overcurrent and short circuits in industrial control panels and distribution boards. The D curve means it tolerates high inrush currents — typical for motor, transformer, or welding loads — without nuisance tripping, while still clearing faults at 15 kA per EN 60898 or 20 kA per IEC 60947-2. It snaps onto a DIN rail (2 modular width units, 36 mm wide) and mounts in any position, with a depth of 76 mm and an installation depth of 70 mm, so it fits standard enclosures without extra clearance.

Ratings and derating — what they mean on the panel

At 35 °C ambient the breaker carries the full 40 A; at 40 °C it derates to 37.56 A, at 50 °C to 34.96 A, and at 60 °C to 32.16 A — so if the panel runs hot, size the upstream protection for the derated value, not the nameplate.

Certified to IEC/EN 60898-1, IEC/EN 60947-2, and UL 1077, with a halogen-free, silicon-free design. Compliance documentation (RoHS, REACH) is available with the shipment.

Frequently asked questions

What is the breaking capacity of 5SY7240-8?

15 kA per EN 60898 and 20 kA per IEC 60947-2; at DC per IEC 60947-2 it is rated 15 kA.

Will 5SY7240-8 drop into a panel that was specified around 5SY7206-7CC without rewiring?

Both are 2-pole SENTRON MCBs with the same 36 mm width and DIN-rail mount, so the footprint is identical — but the 5SY7240-8 is a 40 A D-curve, while the 5SY7206-7CC is a different rating/curve; verify the branch-circuit protection requirements before swapping.

What compliance documentation does Siemens provide for 5SY7240-8?

The breaker carries IEC/EN 60898-1, IEC/EN 60947-2, and UL 1077 certifications, is halogen-free and silicon-free, and RoHS/REACH declarations are available with the shipment.

How do I get current pricing and availability for 5SY7240-8?

Submit an RFQ — the part is sourced to order through independent distribution, and a current price and lead time will be confirmed at quote time.

MPN
5SY7240-8