Siemens 5SY7302-8CC — 3-Pole MCB (DIN Rail)

Siemens 5SY7302-8CC SENTRON MCB, D-Curve 2A 3P 50kA

MPN5SY7302-8CC

Siemens SENTRON 5SY7302-8CC miniature circuit breaker, D-curve, 3-pole, 2 A rated, 50 kA breaking capacity per IEC 60947-2, 440 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY7302-8CC — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationMechanical engineering / industry
5SY7302-8CC — Protection
ParameterValue
Tripping characteristic (curve)D
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Pollution degree3
5SY7302-8CC — Electrical
ParameterValue
Rated current (AC)2 A
Rated voltage (AC, multi-phase)440 V
5SY7302-8CC — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
Combined terminal, topYes
Combined terminal, bottomYes
Fastening methodQuick assembly system
SealableYes
5SY7302-8CC — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of surrounding temperaturemax. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C

Product details

Siemens 5SY7302-8CC — D-curve MCB for motor and transformer branch circuits

Three-pole design (3P) with combined top and bottom terminals, quick-assembly mounting, and any-position installation. The 54 mm width occupies 3 modular units on a DIN rail.

D-curve trips between 10× and 20× In (20–40 A magnetic release), sized for motor starting and transformer energisation where a C-curve would nuisance-trip on inrush. The 2 A rating at 35 °C derates to 1.89 A at 40 °C and 1.71 A at 55 °C — if your enclosure runs hot, factor the thermal curve into the branch-circuit sizing. The 50 kA SCCR at 440 V AC per IEC 60947-2 covers most industrial supply points; verify against your transformer kVA and upstream breaker let-through.

D-curve selectivity and coordination note

For selectivity studies: the D-curve's magnetic threshold at 20–40 A means downstream C-curve MCBs on lighting or control circuits will clear before this breaker trips on a low-level fault. Upstream, verify the 50 kA rating against your transformer's short-circuit capacity. The 440 V AC rating covers 400 V and 415 V systems common in European and Asian industrial plants; 50/60 Hz rated.

MPN
5SY7302-8CC