Siemens 5SY7316-7 — Miniature Circuit Breakers (MCB)

Siemens 5SY7316-7 SENTRON MCB, 3P C-Curve, 15kA IEC

MPN5SY7316-7
Active

Siemens SENTRON 5SY7316-7, 3-pole miniature circuit breaker, C-curve, 15 kA (IEC 60898-1) / 25 kA (IEC 60947-2), 400 V AC, 60 V DC, 3 MW units, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SY7316-7 — Ratings
ParameterValue
Overvoltage categoryIII
5SY7316-7 — Mechanical
ParameterValue
Width54 mm
Height90 mm
Depth76 mm

Product details

The 15 kA breaking capacity per IEC 60898-1 is the standard residential/commercial rating; the 25 kA per IEC 60947-2 is the industrial rating that governs when this breaker is applied in an industrial panel with higher available fault current. At DC, it interrupts 15 kA at 60 V (max 72 V operating), so it also handles DC distribution in control cabinets or solar combiner boxes. The UL 1077 rating of 5 kA confirms its acceptance as a supplementary protector in North American panels — not a branch-circuit primary, but a recognized component for internal equipment protection. This is a current-production part (lifecycle stage: current), so it is sourced through the standard Siemens distribution channel.

Selectivity and coordination

The 5SY7316-7 carries dual-standard breaking capacities: 15 kA under IEC 60898-1 (the household standard) and 25 kA under IEC 60947-2 (the industrial standard). The C-curve's magnetic trip threshold (5–10× In) also aids selectivity: a downstream B-curve breaker will trip first on a low-level fault, while this holds for the motor start.

Rated for ambient temperatures from -40 °C to +75 °C, with humidity derating: max 95% RH at 55 °C, tapering to 35% at 75 °C.

Panel integration

Snaps onto 35 mm DIN rail via the quick-assembly system — no tools needed for mounting or removal. 3 MW units wide (54 mm), 70 mm installation depth behind the panel surface, 76 mm overall depth including the front. No neutral conductor switching — this is a 3-pole breaker for 3-phase loads only; the neutral must be handled separately if required.

Frequently asked questions

What is the breaking capacity of 5SY7316-7?

15 kA per IEC 60898-1, 25 kA per IEC 60947-2 at 400 V AC, and 15 kA at 60 V DC per IEC 60947-2. Under UL 1077 it is rated 5 kA.

Will 5SY7316-7 drop into a panel specified around 5SY4304-7CV?

Both are 3-pole SENTRON MCBs on the same 3 MW DIN-rail footprint, so the mechanical fit is identical. The difference is in the trip curve and ratings — verify the 5SY4304-7CV's curve and breaking capacity against your design before substituting.

Where can I buy 5SY7316-7?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What compliance documentation does Siemens provide for 5SY7316-7?

The part is certified to IEC / EN 60898-1, IEC / EN 60947-2, and UL 1077. It is halogen-free and silicon-free, which supports RoHS and REACH compliance declarations.

MPN
5SY7316-7