Siemens 5SY7325-8CC — 3-Pole MCB (DIN Rail)

Siemens 5SY7325-8CC SENTRON MCB, 3P, 25 A, D Curve, 25 kA IE

MPN5SY7325-8CC

Siemens SENTRON 5SY7325-8CC, 3-pole miniature circuit breaker, 25 A rated current, D tripping characteristic, 25 kA breaking capacity per IEC 60947-2, 400 V AC, 54 mm wide (3 MW), halogen- and silicon-free.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY7325-8CC — Identification
ParameterValue
Design / model code5SY7CC
Brand nameSENTRON
Number of poles3
Suitability for operationMechanical engineering / industry
5SY7325-8CC — Protection
ParameterValue
Tripping characteristic (curve)D
Breaking capacity per IEC 60947-225 kA
Overvoltage categoryIII
IP protection classIP20, with connected conductors
5SY7325-8CC — Electrical
ParameterValue
Rated current (AC)400 V
Rated voltage (AC, multi-phase)440 V
Rated frequency50/60 Hz
5SY7325-8CC — Mechanical
ParameterValue
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Combined terminal, topYes
Combined terminal, bottomYes
SealableYes
5SY7325-8CC — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of surrounding temperaturemax. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C

Product details

Siemens 5SY7325-8CC — 3-pole D-curve MCB for motor and industrial loads

The Siemens 5SY7325-8CC is a 3-pole miniature circuit breaker from the SENTRON 5SY7 series, rated 25 A at 400 V AC with a D tripping characteristic. The 25 kA breaking capacity per IEC 60947-2 gives fault-clearing headroom in industrial panels with high available fault current; the UL 1077 / CSA C22.2 No. 235 rating is 5 kA, so verify the SCCR if the assembly is listed under North American codes. Tightening torque is 2.5–3.5 N·m.

The 5 kA rating under UL 1077 / CSA C22.2 No. 235 is a supplementary-protector classification; if the panel requires a UL 489 listed branch-circuit breaker, this part may not meet that listing. Overvoltage category III (distribution level) confirms it is rated for fixed-installation use downstream of the main service entrance. The D tripping characteristic (10–20× In) is the key selection parameter for motor feeders and inductive loads. At 25 A, the magnetic trip threshold is 250–500 A, which rides through the inrush of a 7.5 kW motor (DOL start) without opening. For resistive loads or general-purpose distribution, a C-curve sibling would be a better fit — the D curve is deliberately slower to clear low-level overloads.

The sealable feature (padlockable toggle) allows lockout/tagout without additional accessories. Touch protection is integral (IP20 with connected conductors), so no finger-safe covers are needed on the terminals in a closed panel.